In vivo evaluation of the Phenox CRC mechanical thrombectomy device in a swine model of acute vessel occlusion.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Mechanical thrombectomy in ischemic stroke is of increasing interest as it is a promising strategy for fast and efficient recanalization. Several thrombectomy devices have been introduced to the armentarium of mechanical thrombectomy. Currently, new devices are under development and are continuously added to the neurointerventional tool box. Each device advocated so far has a different design and mechanical properties in terms of thrombus-device interaction. Therefore, a systematic evaluation under standardized conditions in vivo of these new devices is needed. The purpose of this study was to evaluate the efficiency, thrombus-device interaction, and potential complications of the novel Phenox CRC for distal mechanical thrombectomy in vivo. MATERIALS AND METHODS The device was evaluated in an established animal model in the swine. Recanalization rate, thromboembolic events, vasospasm, and complications were assessed. Radiopaque thrombi (2 cm length) were used for the visualization of thrombus-device interaction during retrieval. The Phenox CRC (4 mm diameter) was assessed in 15 vessel occlusions. For every occlusion a maximum of 3 retrieval attempts were performed. RESULTS Complete recanalization (TICI 3/TIMI 3) was achieved in 86.7% of vessel occlusions. In 66.7% (10/15), the first retrieval attempt was successful, and in 20% (3/15), the second attempt led to complete recanalization of the parent artery. In 2 cases (13.3%) thrombus retrieval was not successful (TICI 0/TIMI 0). In 1 case (6.7%) a minor embolic event occurred in a small side branch. No distal thromboembolic event was observed during the study. Thrombus-device interaction illustrated the entrapment of the thrombus by the microfilaments and the proximal cage of the device. No significant thrombus compression was observed. No vessel perforation, dissection, or fracture of the device occurred. CONCLUSIONS In this small animal study, the Phenox CRC was a safe and effective device for mechanical thrombectomy. The unique design with a combination of microfilaments and proximal cage reduces thrombus compression with a consequently high recanalization and low complication rate.
منابع مشابه
Mechanical thrombectomy for acute ischemic stroke: thrombus-device interaction, efficiency, and complications in vivo.
BACKGROUND AND PURPOSE Mechanical thrombectomy is a promising new modality of interventional stroke treatment. The various devices differ with regard to where they apply force on the thrombus, taking a proximal approach such as aspiration devices or a distal approach such as basket-like devices. The study compares the in vivo effectiveness and thrombus-device interaction of these 2 approaches. ...
متن کاملA dedicated animal model for mechanical thrombectomy in acute stroke.
BACKGROUND Recent studies have focused on mechanical thrombectomy as a means to reduce the time required for revascularization and increase the revascularization rate in acute stroke. To date no systematic evaluation has been made of the different mechanical devices in this novel and fast-developing field of endovascular interventions. To facilitate such evaluations, we developed a specific in ...
متن کاملThe Phenox Clot Retriever as Part of a Multimodal Mechanical Thrombectomy Approach in Acute Ischemic Stroke: Single Center Experience in 56 Patients
Purpose. We analyzed our experience with the phenox clot retriever as part of a multimodal mechanical thrombectomy (MTE) approach in acute ischemic stroke. Methods. 56 patients were treated by MTE with the phenox clot retriever alone or in combination with other modalities. Results. Overall we achieved TICI 2b/3 reperfusion rates of 61,9%. In multimodally treated patients we achieved reperfusio...
متن کاملThe Trevo device: preclinical data of a novel stroke thrombectomy device in two different animal models of arterial thrombo-occlusive disease.
BACKGROUND The currently available mechanical devices fail to achieve recanalization in as many as 20-40% of proximal arterial occlusion strokes. OBJECTIVE The preclinical evaluation of the safety and efficacy of a novel thrombectomy device designed to achieve immediate flow restoration by quickly removing clot is reported. METHODS Four confirmatory animal studies were performed with the Tr...
متن کاملEndothelial trauma from mechanical thrombectomy in acute stroke: in vitro live-cell platform with animal validation.
BACKGROUND AND PURPOSE Endovascular thrombectomy has shown promise for the treatment of acute strokes resulting from large-vessel occlusion. Reperfusion-related injury may contribute to the observed decoupling of angiographic and clinical outcomes. Iatrogenic disruption of the endothelium during thrombectomy is potentially a key mediator of this process that requires further study. METHODS An...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 31 5 شماره
صفحات -
تاریخ انتشار 2010