A new valve for draw-over anaesthesia.
نویسندگان
چکیده
The Diamedica non-rebreathing valve has been developed for use in draw-over anaesthesia and can be positioned at the common gas outlet. Its performance was evaluated against the Laerdal, Ruben and Ambu valves under laboratory conditions. Valve resistance during inspiration and expiration was simulated over a range of constant flow conditions. During flows ranging from 5 to 45 l.min(-1) , the Diamedica and Ruben valves exhibited a negligible resistance of < 150 Pa, with the Laerdal and Ambu valves achieving resistance of < 200 Pa. To assess the effects of sterilisation, this procedure was repeated following autoclaving, after which the Diamedica valve exhibited resistance to flow of < 150 Pa at 25 l.min(-1) for inlet resistance and 35 l.min(-1) for outlet resistance. The Diamedica, Ambu and Laerdal valves demonstrated resistance of < 100 Pa when saturated with water, while the Ruben valve exhibited resistance > 500 Pa.
منابع مشابه
Modification of a draw-over vaporizer for use with sevoflurane.
BACKGROUND Draw-over anaesthesia is widely used throughout the developing world, in disaster areas and in military anaesthesia when the supply of pressurized oxygen is unreliable. To date, no draw-over vaporizer has been able to deliver sufficient concentrations of sevoflurane for use in inhalation induction of anaesthesia. A laboratory study to assess the performance of a new vaporizer (DDV2) ...
متن کاملVentilatory effects of isoflurane: a comparison with halothane in a draw-over system.
Halothane and isoflurane were studied using a draw-over anaesthetic system in two groups each of 25 patients to compare the ventilatory effects of the two agents in field anaesthesia. Respiratory variables were measured and it was confirmed that isoflurane is a more potent respiratory depressant than halothane, but satisfactory anaesthesia for short procedures was possible.
متن کاملSevoflurane Output in the Isoflurane/Halothane Diamedica Draw-over Vaporiser.
INTRODUCTION Draw-over anaesthesia remains an attractive option for conduct of anaesthesia in austere conditions. The Diamedica Draw-over Vaporiser (DDV) is a modern draw-over vaporiser and has separate models for isoflurane/halothane and sevoflurane. MATERIALS AND METHODS A laboratory study was done to measure sevoflurane output in an isoflurane/ halothane DDV. We did 3 series of experiments...
متن کاملAN INNOVATIVE SURGIC AL TECHNIQUE FOR CONTINUOUS SUTURING OF PROSTHESIS IN MITR AL VALVE REPL A CEMENT
Mitral valve replacement (MVR) is usually performed in two methods of running and interrupted suturing. In running method, the suturing of the valve is usually with some traction on the annulus and also there is a risk of aortic valve injury. This study was conducted to evaluate a new technique for suturing to avoid these complications and decrease the time of cardiac arrest. One hundred an...
متن کاملBicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva
Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anaesthesia
دوره 65 11 شماره
صفحات -
تاریخ انتشار 2010