Reproducibility of Determining Anaerobic Capacity Using Treadmill Ergometry
نویسندگان
چکیده
To implement a method measuring anaerobic capacity within the field of training control, the reproducibility of the results is of deciding significance. In this study, we examined the test-retest-reliability of the most commonly used method for measuring anaerobic capacity to date, modified according to Monod and Scherrer, on a motorized treadmill. Ten healthy, athletically active, male participants carried out two defined test series of each three sprint tests with an interval of one week. The work output of each participant and test series was calculated from this data. These results, as well as the running time of the sprint tests were graphically plotted using a work-exhaustion-time-diagram. After calculating a linear regression, the point of intersection of the regression line with the y-axis (y-intercept) was defined as the measure of anaerobic capacity (AC). The mean AC determined from the first sprint test series was 1.4 ± 0.8KJ and from the second sprint test series 1.2 ± 0.06KJ. The AC shows a mean difference of 18.4% (95% CI: 10.5 26.4), which is statistically significantly higher (p=0.004) than a tolerable mean difference level of 5%. Based on this difference, the described method does not seem suitable as a training control in competitive sport. This method, however, could be implemented for talent sighting.
منابع مشابه
Maximal shuttle running over 40 m as a measure of anaerobic performance.
Over the last decade increasing interest has been shown in the measurement of anaerobic power and capacity in athletic men. These physiological characteristics have been determined predominantly using cycle ergometry and treadmill sprinting. The purpose of the present study was to examine the relationship between 40-m maximal shuttle run times and performance indices obtained during treadmill s...
متن کاملCardiorespiratory responses to standing arm ergometry in patients with ischemic heart disease. Comparison with the results of treadmill exercise.
To compare cardiorespiratory responses to standing arm ergometry and treadmill exercise, two graded exercise stress tests were performed in 30 patients with ischemic heart disease (IHD). Cardiac catheterization and expired gas analyses were also done. Standing arm ergometry was discontinued because of arm fatigue in 15 (50%) patients, whereas treadmill exercise was stopped due to leg fatigue in...
متن کاملComparison of VO2 Peak during Treadmill and Cycle Ergometry in Severely Overweight Youth.
The purpose of this study was to compare peak cardiorespiratory parameters during treadmill and cycle ergometry in severely overweight youth. Twenty-one participants from the Committed to Kids Pediatric Weight Management program at the Louisiana State University Health Sciences Center volunteered. Participants completed peak treadmill and cycle ergometer tests on separate days. In order to exam...
متن کاملEvaluation of a new treadmill exercise protocol.
STUDY OBJECTIVES To confirm that a newly drafted treadmill exercise protocol designed on a theoretical basis to span a range of 0 to 200 W with approximately 25-W increments by alteration of either speed or grade from one stage to the next should correspond to a standard bicycle protocol consisting of 25-W steps. DESIGN Randomized, crossover study to compare both exercise test modes. STUDY ...
متن کاملSports-specific fitness testing in squash.
Maximum oxygen uptake and the running speed at the anaerobic threshold were determined during treadmill running. Performance in these laboratory tests and performance on a squash-specific field test were compared and examined with respect to subjective ratings of squash fitness. The field test was performed in a squash court. Six light bulbs were connected to a programming device causing indivi...
متن کامل