Single unit conduction velocities from averaged nerve cuff electrode records in freely moving cats.
نویسندگان
چکیده
The conduction velocity of peripheral neurons recorded by wire microelectrodes implanted in intact, freely moving cats was determined on-line using the technique of spike-triggered averaging of nerve cuff electrode records described here. Axonal velocity was estimated from the conduction latency between two adjacent sets of tripolar recording electrodes inside a cuff, thereby avoiding uncertainties that could arise from differences in spike shape, variable conduction distance, or unknown stimulus utilization time. This method rendered conduction velocity values for individual afferent and efferent myelinated fibers ranging from 27 to 120 m/sec, estimated with an uncertainty of +/-5%. In addition, predictions from theoretical models relating extracellular potential amplitude, wavelength, and conduction velocity were confirmed experimentally for en passant records obtained from intact myelinated fibers.
منابع مشابه
Cat hindlimb motoneurons during locomotion. I. Destination, axonal conduction velocity, and recruitment threshold.
Fine flexible wire microelectrodes chronically implanted in the fifth lumbar ventral root (L5 VR) of 17 cats rendered stable records of the natural discharge patterns of 164 individual axons during locomotion on a treadmill. Fifty-one out of 164 axons were identified as motoneurons projecting to the anterior thigh muscle group. For these axons, the centrifugal propagation of action potentials w...
متن کاملConduction studies in peripheral cat nerve using implanted electrodes: I. Methods and findings in controls.
Silicone rubber cuff and patch electrodes with multiple contacts were implanted along the sciatic-tibial-plantar nerves in cat for repeated studies of conduction properties of normal peripheral nerve over periods of time. The contacts were used in various combinations for precise localization of changes in conduction velocities and excitability along the extent of normal nerves. In this paper t...
متن کاملConduction Velocity Changes along Lumbar
Though peripheral conduction velocity is widely used to characterize afferent fibers according to somatosensory modality, disagreement exists as to whether or not conduction velocity varies along such an axon's length. Therefore, in this experiment, conduction velocities were measured over very short axonal segments (7.5 to 15 mm) within the posterior tibia1 nerve, sciatic nerve, and L7 dorsal ...
متن کاملSpiral nerve cuff electrode for recordings of respiratory output.
The feasibility of using the spiral nerve cuff electrode design for recordings of respiratory output from the hypoglossal (HG) and phrenic nerves is demonstrated in anesthetized, paralyzed, and artificially ventilated cats. Raw neural discharges of the HG nerve were analyzed in terms of signal-to-noise ratios and frequency spectra. The rectified and integrated moving average activity of the HG ...
متن کاملPossibilities offered by implantable miniaturized cuff-electrodes for insect neurophysiology
Recent advances in microsystems technology led to a miniaturization of cuff-electrodes, which suggests these electrodes not just for long-term neuronal recordings in mammalians, but also in medium-sized insects. In this study we investigated the possibilities offered by cuff-electrodes for neuroethology using insects as a model organism. The implantation in the neck of a tropical bushcricket re...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of neuroscience methods
دوره 4 3 شماره
صفحات -
تاریخ انتشار 1981