Effects of midstream collection and the menstrual cycle on urine particles and dipstick urinalysis among healthy females.
نویسندگان
چکیده
g/L). We also analyzed an aliquot of each of the three samples for 13 consecutive days (a total of 39 samples); 38 of the 39 (97.5%) were placed correctly, and the 39th was placed in the category immediately above the correct category. We diluted a urine sample containing 6.3 mol/L mmol/L added to a sample containing 1.15 mol/L (146 g/L) iodine did not change the iodine concentration measured by the AutoAnalyzer (1.14 –1.15 mol/L) or by Fast B [remaining in the 0.79 –1.18 mol/L (100 –150 g/L) category]; for this experiment, other KIO 3 calibra-tors were used to create the category of 0.79 –1.18 mol/L (100 –150 g/L). No change in iodine concentration was detected by either the AutoAnalyzer or Fast B after the addition of potassium thiocyanate at concentrations of 0.172, 0.344, or 0.688 mmol/L or of d-glucose up to 56 mmol/L (10.14 g/L). The placement of values within the ranges described here satisfies most epidemiologic purposes (1) and is more cost-effective than analyzing and reporting individual samples. One technician can easily measure 200 samples in a working day, and depending on salaries, the cost may be less than US $0.10/sample. One of us (D.G.) trained two technicians from a developing country in African to be proficient in the method after 3 days of instruction and practice. The investment in equipment is low, and except for pipettes, the only instrument is the heating block, which might be replaced by a boiling water bath if necessary. In conclusion, the Fast B method described here is rapid, simple, reliable, flexible, and inexpensive and provides an attractive means for assessing iodine nutrition in populations, especially in developing countries. We thank the Micronutrient Initiative (Ottawa, Canada) for financial support, and colleagues in the International Council for the Control of Iodine Deficiency Disorders (ICCIDD) for providing samples and helpful discussion. 4. Standardization of ultrasound and urinary iodine determination for assessing iodine status: report of a technical consultation. Ammonium persulfate: a safe alternative oxidizing reagent for measuring urinary iodine. Simple method for assessing urinary iodine, including preliminary description of a new rapid technique (" Fast B "). For urinalysis, midstream collection is recommended (1– 3). Health-associated reference limits for leukocyte and erythrocyte counts in female urine are important for detecting hematuria, pyuria, and urinary tract infection (3). To understand the effects of urinary collection and the menstrual cycle on urinalysis, we examined first-stream and midstream …
منابع مشابه
Morphologic changes in urine particles during the menstrual cycle.
To the Editor: Our previous study demonstrated that the numbers of epithelial cells and erythrocytes in midstream urine vary significantly during the men-strual cycle (1). We now report the influence of the menstrual cycle on the number and morphology of urine particles. Specimens were obtained from 67 healthy female students (age range, 18 –20 years) at the College of Medical Technology. All p...
متن کاملImpact of menstrual cycle on the diagnostic performance of LCR, TMA, and PCE for detection of Chlamydia trachomatis in home obtained and mailed vaginal flush and urine samples.
OBJECTIVES To assess the impact of the menstrual cycle on the diagnostic performance of various assays for detection of Chlamydia trachomatis in home obtained and mailed vaginal flush and urine specimens. METHODS A ligase chain reaction assay (LCR; Abbott Laboratories), a transcription mediated amplification assay (TMA; Gen-Probe), and an enzyme amplified immunoassay (PCE; Dako Diagnostics) w...
متن کاملEffectiveness of five different approaches in management of urinary tract infection: randomised controlled trial
OBJECTIVE To assess the impact of different management strategies in urinary tract infections. DESIGN Randomised controlled trial. SETTING Primary care. PARTICIPANTS 309 non-pregnant women aged 18-70 presenting with suspected urinary tract infection. INTERVENTION Patients were randomised to five management approaches: empirical antibiotics; empirical delayed (by 48 hours) antibiotics; o...
متن کاملThe validity of the uriscreen test for early detection of urinary tract infection in children.
OBJECTIVE To determine the validity of the Uriscreen, a rapid diagnostic test based on the detection of urine catalase for the early detection of urinary tract infection (UTI) in children, compared with standard urinalysis and dipstick tests. STUDY DESIGN. Cross-sectional study. STUDY POPULATION Children 1 month to 17 years of age who presented to the emergency department of a pediatric terti...
متن کاملSex and age differences in serum potassium in the United States.
midstream urine samples. Epithelial cell and erythrocyte counts in midstream urine specimens changed significantly during the menstrual cycle (Fig. 1). Epithelial cell counts during the luteal phase were higher than those during the other three phases in midstream urine. Erythrocyte counts during the menstrual phase were higher than those during the other three phases. Other cell counts did not...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 49 1 شماره
صفحات -
تاریخ انتشار 2003