Construction Details of an Autoradiographic-Based Rat Brain Phantom for Emission Tomography

نویسندگان

  • D. A. Dougherty
  • J. Nissanov
  • G. R. Gindi
چکیده

A digital brain phantom was created from rat brain autoradiographic (AR) data for use in emission computed tomography studies. The animal tissue was radio-labeled with [C]-2-deoxyglucose, a functional analog of the PET agent [F]-fluoro-deoxyglucose. Following sacrifice of the animal, serial tissue sections were cut at 20 m thickness, digitized, and calibrated to represent the ground truth 2D relative spatial distribution of radionuclide within the tissue. A 3D representation was achieved by digital alignment of the serial AR images to corresponding video blockface images acquired at the time of cutting. In addition, a magnetic resonance data set was co-registered to the AR and blockface data using the AIR algorithm. This paper is concerned with outlining the details of construction for this phantom.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Background-Based Delineation of Internal Tumor Volumes on Static Positron Emission Tomography in a Phantom Study

Objective(s): Considering the fact that the standardized uptake value (SUV) of a normal lung tissue is expressed as x±SD, x+3×SD could be considered as the threshold value to outline the internal tumor volume (ITV) of a lung neoplasm. Methods: Three hollow models were filled with 55.0 kBq/mL fluorine18- fluorodeoxyglucose (18F-FDG) to represent tumors. The models were fixed to a barrel filled w...

متن کامل

Comparison of Count Normalization Methods for Statistical Parametric Mapping Analysis Using a Digital Brain Phantom Obtained from Fluorodeoxyglucose-positron Emission Tomography

Objective(s): Alternative normalization methods were proposed to solve the biased information of SPM in the study of neurodegenerative disease. The objective of this study was to determine the most suitable count normalization method for SPM analysis of a neurodegenerative disease based on the results of different count normalization methods applied on a prepared digital phantom similar to one ...

متن کامل

Design and Construction of an Affordable Phantom for Electron Density Measurement and Linearity Tests of Computed Tomography Systems

Introduction: The performance of computed tomography is routinely checked using phantoms, which are known as important diagnostic imaging tools. Depending upon the aim of the study, different phantoms are designed, while trying to satisfy certain levels of diversities in their application. Material and Methods: The present study describes the...

متن کامل

Computerized Biological Brain Phantom for Evaluation of PET and SPECT Reconstruction

A digital brain phantom was created from available primate autoradiographic (AR) data for use in emission computed tomography studies. The tissue was radio-labelled with a functional analogue of the PET agent [18F]-fluoro-deoxyglucose (FDG). Following sacrifice of the animal, film records from serial 20 m thickness sections were digitized and calibrated to obtain ground truth 2D spatial distrib...

متن کامل

Automated three-dimensional analysis of histological and autoradiographic rat brain sections: application to an activation study.

Besides the newly developed positron emission tomography scanners (microPET) dedicated to the in vivo functional study of small animals, autoradiography remains the reference technique widely used for functional brain imaging and the gold standard for the validation of in vivo results. The analysis of autoradiographic data is classically achieved in two dimensions (2D) using a section-by-sectio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998