Detectability of Absorption and Reduced Scattering Coefficients in Frequency-Domain Measurements Using a Realistic Head Phantom
نویسندگان
چکیده
Detection limits of the changes in absorption and reduced scattering coefficients were investigated using a frequency-domain near-infrared system in a realistic head phantom. The results were quantified in terms of the maximum detectable depth for different activation volumes in the range of 0.8-20 microliters. The non-linear relation between the maximum detectable depth and the magnitude of changes in the absorption coefficient conform well with the Born approximation to the diffusion equation. The minimal detectable changes in the reduced scattering coefficient measured in terms of the phase signal were found to be approximately twice as large as that of the absorption coefficient using the AC signal for the same volume and at the same depth. The phase delay, which can be used to quantify the fast neuronal optical response in the human brain, showed a linear dependence on the reciprocal of the reduced scattering coefficient, as predicted by the Rytov approximation.
منابع مشابه
Frequency-domain method for measuring spectral properties in multiple-scattering media: methemoglobin absorption spectrum in a tissuelike phantom.
We have measured the optical absorption and scattering coefficient spectra of a multiple-scattering medium (i.e., a biological tissue-simulating phantom comprising a lipid colloid) containing methemoglobin by using frequency-domain techniques. The methemoglobin absorption spectrum determined in the multiple-scattering medium is in excellent agreement with a corrected methemoglobin absorption sp...
متن کاملReconstruction of optical properties of phantom and breast lesion in vivo from paraxial scanning data.
We report on the reconstruction of absorption and reduced scattering coefficients of breast tissue in vivo of a patient with mastopathic disease. Distributions of times of flight of photons through the compressed breast were recorded by paraxial scanning. From data measured at four different source-detector offsets optical properties were reconstructed within the linear Rytov approximation by a...
متن کاملTemperature-dependent optical properties of Intralipid measured with frequency-domain photon-migration spectroscopy.
We present the temperature dependence of absorption and reduced scattering coefficients of 1.8% Intralipid measured by frequency-domain photon-migration spectroscopy between 710 and 850 nm. These measurements were made in the physiologically relevant 30 to 40 degrees C temperature range. The temperature coefficients for absorption were consistent during heating and cooling and follow closely ot...
متن کاملThree-dimensional phantoms for curvature correction in spatial frequency domain imaging
The sensitivity to surface profile of non-contact optical imaging, such as spatial frequency domain imaging, may lead to incorrect measurements of optical properties and consequently erroneous extrapolation of physiological parameters of interest. Previous correction methods have focused on calibration-based, model-based, and computation-based approached. We propose an experimental method to co...
متن کاملTissue phantom for optical diagnostics based on a suspension of microspheres with a fractal size distribution.
We demonstrate experimentally the possibility of reproducing the phase function, absorption, and scattering coefficients of a real biological tissue (adult brain white matter and liver) using a suspension of polystyrene microspheres with a fractal size distribution. The design of a light scattering goniometer with a cylindrical cell in air is discussed, and phase function measurements using the...
متن کامل