Dark blood cine for improved Visualization of Intracavitary Structures (iVIS)
نویسندگان
چکیده
Background In bright blood imaging, partial volume averaging of small moving intracavitary structures and surrounding bright blood often degrades the depiction of such morphology. Therefore, structures including papillary muscles, trabeculations, and intracardiac masses are better visualized with dark blood (DB) techniques. DB imaging also provides better image contrast for low signal structures since it avoids the dynamic range compression present in bright blood imaging. DB sequences are thus the standard imaging tool for assessing cardiac morphology, but they do not contain information about motion, for example of mobile intracardiac masses. We therefore developed a novel dark blood gradient echo cine sequence that simultaneously depicts morphology, motion of intracardiac structures, and cardiac contraction.
منابع مشابه
Pnm-1: Applications of Hysterosonography for The Detection of Intracavitary Uterine Abnormalities
Hysterosonography (SHG) is a new noninvasive technique that involves the slow infusion of sterile saline solution into the uterus during ultrasound imaging. Expansion of endometrial cavity by SHG allows optimal visualization and plays an important role in the evaluation of abnormalities related to the uterus. The most common indications for hysterosonography are: abnormal uterine bleeding both ...
متن کاملBenefits and Pitfalls in the Use of Contrast Agents in 4D Flow Imaging
Introduction Recent advances in hardware and the emergence of various accelerated techniques have facilitated the use of 4D flow imaging for the simultaneous assessment of vascular anatomy and cine velocity fields. However, further advances in decreasing scan time and/or improving spatial resolution and coverage are complicated by the limited signal-to-noise ratio (SNR). Bock et al. [1] demonst...
متن کاملPatient and device related factors affecting artifact size and cardiac visualization when performing cardiac MRI in patients with implanted defibrillators
Methods Imaging studies and device records for 45 consecutive patients with an ICD undergoing cardiac MRI were reviewed. Generator artifact diameter was measured on axial dark-blood sequences when available and compared among device manufacturers. In 28 of these patients who had available chest x-rays, minimum distance of the generator from the heart border was measured and compared to the dist...
متن کاملSelective pulmonary venous flow visualization and quantification by flow-sensitive four-dimensional cine magnetic resonance imaging facilitates and improves the accurate diagnosis of partial anomalous pulmonary venous drainage
Methods In six patients with echocardiographically suspected PAPVD, anatomy was evaluated using standard magnetic resonance imaging including angiography. Functional analysis included shunt calculations from standard flowmeasurements. Furthermore, 4D VEC MRI was used for visualization of maldraining pulmonary veins and quantification of flow via the maldraining veins and interatrial communicati...
متن کاملCardiac MRI: T2-Mapping Versus T2-Weighted Dark-Blood TSE Imaging for Myocardial Edema Visualization in Acute Myocardial Infarction Kardiales MRT: T2-Mapping versus T2-gewichtete TSE-Bildgebung für die Visualisierung eines Myokardödems beim akuten Myokardinfarkt
Ziel: Ziel der vorliegenden Studie war es, zu untersuchen mit welcher diagnostischen Genauigkeit das T2-Mapping die Visualisierung eines Myokardödems beim akuten Myokardinfarkt (AMI) erlaubt und diese diagnostische Genauigkeit mit der des gegenwärtigen Standards für die myokardiale Ödembildgebung (T2-gewichtete, dark-blood präparierte TSE-Sequenz) zu vergleichen. Material und Methoden: 29 Patie...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 16 شماره
صفحات -
تاریخ انتشار 2014