Does plate type influence the clinical outcomes and implant removal in midclavicular fractures fixed with 2.7-mm anteroinferior plates? A retrospective cohort study

نویسندگان

  • Alex K Gilde
  • Clifford B Jones
  • Debra L Sietsema
  • Martin F Hoffmann
چکیده

BACKGROUND The purpose of this study was to evaluate surgical healing rates, implant failure, implant removal, and the need for surgical revision with regards to plate type in midshaft clavicle fractures fixed with 2.7-mm anteroinferior plates utilizing modern plating techniques. METHODS This retrospective exploratory cohort review took place at a level I teaching trauma center and a single large private practice office. A total of 155 skeletally mature individuals with 156 midshaft clavicle fractures between March 2002 and March 2012 were included in the final results. Fractures were identified by mechanism of injury and classified based on OTA/AO criteria. All fractures were fixed with 2.7-mm anteroinferior plates. Primary outcome measurements included implant failure, malunion, nonunion, and implant removal. Secondary outcome measurements included pain with the visual analog scale and range of motion. Statistically significant testing was set at 0.05, and testing was performed using chi-square, Fisher's exact, Mann-Whitney U, and Kruskall-Wallis. RESULTS Implant failure occurred more often in reconstruction plates as compared to dynamic compression plates (p = 0.029). Malunions and nonunions occurred more often in fractures fixed with reconstruction plates as compared to dynamic compression plates, but it was not statistically significant. Implant removal attributed to irritation or implant prominence was observed in 14 patients. Statistically significant levels of pain were seen in patients requiring implant removal (p = 0.001) but were not associated with the plate type. CONCLUSIONS Anteroinferior clavicular fracture fixation with 2.7-mm dynamic compression plates results in excellent healing rates with low removal rates in accordance with the published literature. Given higher rates of failure, 2.7-mm reconstruction plates should be discouraged in comparison to stiffer and more reliable 2.7-mm dynamic compression plates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Semitubular plates for acutely displaced midclavicular fractures: a retrospective study of 111 patients followed for 2.5 to 6 years.

OBJECTIVES We designed this study to determine the usefulness of semitubular plates for acute displaced or comminuted fractures of the midclavicle. DESIGN Nonrandomized retrospective study. SETTING A secondary transfer hospital specializing in orthopaedics. PATIENTS From May 1997 to July 2001, 121 patients were treated with a 92% (111) follow-up rate. The mean follow-up time was 3.5 years...

متن کامل

Superior versus anteroinferior plating of clavicle fractures.

Plate fixation of displaced clavicle fractures has proven to be reliable and reproducible, leading to high union rates and a low rate of associated complications. However, the decision of whether to place the plate superiorly or anteroinferiorly on the clavicle has remained controversial. The authors performed a retrospective review on a consecutive series of patients who underwent plate fixati...

متن کامل

Elective implant removal in symptomatic patients after internal fixation of proximal humerus fractures improves clinical outcome

BACKGROUND Operative treatment is the standard for severely displaced proximal humerus fractures, but functional impairment can persist. Retaining of the implant can be a reason and in other fracture situations has proved to ameliorate patient satisfaction. The aim of this study was to analyse the functional outcome after locking plate removal in proximal humerus fractures. METHODS In a two-y...

متن کامل

Precontoured Locking Plate Treatment in Mid-Shaft Clavicle Fractures: Outcomes and Complications with a Minimun of 2- Years Follow up

Background: The aim of this study was to evaluate functional outcome and complications with a long term followup (minimum of 2 years post-operative) in patients with mid-shaft clavicle fractures treated with precontoured lockingplates.Methods: We included 41 patients. Goniometric measurement of shoulder range of motion (ROM) was performed,as well as functional evaluation using the rating scale ...

متن کامل

Challenges of Plate Fixation for Vancouver Type-C Fractures after a Well-Fixed Hip Arthroplasty Femoral Stem

The fixation of distal femoral fractures (Vancouver type-C fractures) following a well-fixed hip arthroplasty femoral stem has become a challenging issue for orthopedic surgeons due to the inter-prosthetic biomechanical effects such as negative, positive, and torsional strain. Surgeons have applied a range of constructs to overcome these difficulties. To minimize the risk of inter-prosthetic fr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014