G as a Nalysis and M Onitoring S Ystems for the Rpc D Etector of Cms at Lhc

نویسندگان

  • M. Abbrescia
  • A. Colaleo
  • R. Guida
  • G. Iaselli
  • R. Liuzzi
  • F. Loddo
  • M. Maggi
  • B. Marangelli
  • S. Natali
  • S. Nuzzo
  • G. Pugliese
  • A. Ranieri
  • F. Romano
  • R. Trentadue
  • L. Benussi
  • M. Bertani
  • M. A. Caponero
  • D. Colonna
  • D. Donisi
  • F. L. Fabbri
  • F. Felli
  • M. Giardoni
  • B. Ortenzi
  • M. Pallotta
  • A. Paolozzi
  • L. Passamonti
  • B. Ponzio
  • C. Pucci
  • G. Saviano
  • G. Polese
  • I. Segoni
  • N. Cavallo
  • F. Fabozzi
  • P. Paolucci
  • D. Piccolo
  • C. Sciacca
  • G. Belli
  • A. Grelli
  • M. Necchi
  • S. P. Ratti
  • C. Riccardi
  • P. Torre
  • P. Vitulo
چکیده

The Resistive Plate Chambers (RPC) detector of the CMS experiment at the LHC proton collider (CERN, Switzerland) will employ an online gas analysis and monitoring system of the freon-based gas mixture used. We give an overview of the CMS RPC gas system, describe the project parameters and first results on gas-chromatograph analysis. Finally, we report on preliminary results for a set of monitor RPC.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The RPC system for the CMS experiment at the LHC

The CMS detector at the LHC has a redundant muon system. Two independent muon systems are used in the L1 trigger. One of them is based on wire chambers, the other on RPC detectors. Properly combining the answers of the two systems results in a highly efficient L1 trigger with high flexibility from the point of view of rate control. Simulation results show, however, that the RPC system suffers f...

متن کامل

Threshold dependence of strip clusters for the forward region resistive plate chamber of the CMS/LHC experiment

Strip clusters of muons and background hits induced by gamma rays and spurious pulses are analyzed for the Forward Region Resistive Plate Chamber of the CMS/LHC. In order to perform the analysis, a real size RE2/1 prototype RPC manufactured with the final baseline design of the Forward Region RPCs was tested at the Gamma Irradiation Facility of CERN. Strip cluster sizes for muons and strip clus...

متن کامل

A new Front-End board for RPC detector of CMS

A new Front-End board for the RPC detector of the CMS experiment at LHC is described. It houses two Front-End chips and the Front-End controller, which includes the Synchronization Unit. Its aim is to amplify the delta-like detector signals, ranging from 20 fC to 20 pC, generate fast output pulses and synchronize them with the LHC clock.

متن کامل

Implementation of the data acquisition system for the resistive plate chamber pattern comparator muon trigger in the CMS experiment

This paper presents the implementation of the data acquisition system of the resistive plate chamber (RPC) subdetector in compact muon solenoid (CMS) experiment at the Large Hadron Collider (LHC) in CERN. The described readout system connects with the RPC detector, the RPC link system, the RPC trigger system and the CMS data acquisition system and creates one of multiple metrological systems in...

متن کامل

First results on RB2 muon barrel RPC detector for CMS

The first CMS MB2 station, with one RPC and one DT module, has been tested with a muon beam under a high intensity photon flux at the CERN Gamma Irradiation Facility during the Autumn 2001 test. Results on efficiency, rate capability, cluster size and spatial resolution, for the RPC detector, are reported here. Studies with a small percentage of SF6 in the gas mixture, in order to decrease the ...

متن کامل