On the sensitivity of patient‐specific IMRT QA to MLC positioning errors
نویسندگان
چکیده
Accurate multileaf collimator (MLC) leaf positioning plays an essential role in the effective implementation of intensity modulated radiation therapy (IMRT). This work evaluates the sensitivity of current patient-specific IMRT quality assurance (QA) procedures to minor MLC leaf positioning errors. Random errors of up to 2 mm and systematic errors of +/-1 mm and +/-2 mm in MLC leaf positions were introduced into 8 clinical IMRT patient plans (totaling 53 fields). Planar dose distributions calculated with modified plans were compared to dose distributions measured with both radiochromic films and a diode matrix. The agreement between calculation and measurement was evaluated using both absolute distance-to-agreement (DTA) analysis and gamma index with 2%/2 mm and 3%/3 mm criteria. It was found that both the radiochromic film and the diode matrix could only detect systematic errors on the order of 2 mm or above. The diode array had larger sensitivity than film due to its excellent detector response (such as small variation, linear response, etc.). No difference was found between DTA analysis and gamma index in terms of the sensitivity to MLC positioning errors. Higher sensitivity was observed with 2%/2 mm than with 3%/3 mm in general. When using the diode array and 2%/2 mm criterion, the IMRT QA procedure showed strongest sensitivity to MLC position errors and, at the same time, achieved clinically acceptable passing rates. More accurate dose calculation and measurement would further enhance the sensitivity of patient-specific IMRT QA to MLC positioning errors. However, considering the significant dosimetric effect such MLC errors could cause, patient-specific IMRT QA should be combined with a periodic MLC QA program in order to guarantee the accuracy of IMRT delivery.
منابع مشابه
Inverse Verification of the Dose Distribution for Intensity Modulated Radiation Therapy Patient-specific Quality Assurance Using Dynamic MLC Log Files
The aim of this study was to investigate a novel method for verification of the dose distribution for intensity modulated radiation therapy (IMRT) patient-specific quality assurance (QA) using dynamic multi-leaf collimator (DMLC) log files (Dynalog files). Dynalog files are recorded every 50 ms by using a MLC controller during the IMRT treatment. Dynalog files contain actual MLC positional info...
متن کاملSensitivity of a helical diode array device to delivery errors in IMRT treatment and establishment of tolerance level for pretreatment QA
The aim of this study is to determine the gantry angle and multileaf collimator (MLC) gap error-detection threshold of a diode helical array with an inserted micro-ionization chamber in order to use this device for the pretreatment quality assurance (QA) of intensity-modulated radiation therapy (IMRT) treatments. Implications on the dose-volume histograms (DVHs) of the patient treatments will a...
متن کاملROC analysis in patient specific quality assurance.
PURPOSE This work investigates the use of receiver operating characteristic (ROC) methods in patient specific IMRT quality assurance (QA) in order to determine unbiased methods to set threshold criteria for γ-distance to agreement measurements. METHODS A group of 17 prostate plans was delivered as planned while a second group of 17 prostate plans was modified with the introduction of random m...
متن کاملClinical implementation and error sensitivity of a 3D quality assurance protocol for prostate and thoracic IMRT
This work aims at three goals: first, to define a set of statistical parameters and plan structures for a 3D pretreatment thoracic and prostate intensity-modulated radiation therapy (IMRT) quality assurance (QA) protocol; secondly, to test if the 3D QA protocol is able to detect certain clinical errors; and third, to compare the 3D QA method with QA performed with single ion chamber and 2D gamm...
متن کاملSensitivity of array detector measurements in determining shifts of MLC leaf positions
Using a MatriXX 2D ionization chamber array, we evaluated the detection sensitivity of systematically introduced MLC leaf positioning shifts to test whether the conventional IMRT QA method can be used for quality assurance of an MLC tracking algorithm. Because of finite special resolution, we first tested whether the detection sensitivity was dependent of the locations of leaf shifts and positi...