A 16-Channel Conformal Transceive Coil for 7-T Neuroimaging

نویسندگان

  • K. M. Gilbert
  • A. T. Curtis
  • J. S. Gati
  • L. M. Klassen
  • R. S. Menon
چکیده

Introduction Transmit/receive arrays have been developed to mitigate RF inhomogeneities at high field and to increase SNR. The majority of these designs consist of an array of surface coils or transmission line elements on a cylindrical former. The cylindrical geometry increases transmit uniformity, due to the large distance from the head, while sacrificing transmit efficiency and receive sensitivity. Conformal designs have the potential to increase transmit efficiency (and decrease SAR), while at the same time increasing SNR. A 16-channel transmit/receive coil is presented that conforms to the shape of the head. The decoupling scheme allows for coil elements to have arbitrary shape, size, and location: this flexibility allows coil elements to be both electrically and physically independent—a desired characteristic for parallel imaging. The increased receive sensitivity of the conformal design, coupled with the reduced radiation losses achieved with the individually shielded design (1), creates high SNR. Methods The coil consisted of 16 independently driven transmit/receive channels located on two detachable halves of a head-shaped former (Fig. 1). Each element was curved to conform to the former and the shape chosen to maximize orthogonality of the B1 field to the B0 field. Elements were decoupled using circumferential shields around each element that extended orthogonally from the former. Electrically isolated copper-mesh shields encompassed each coil element at approximately 5-9 mm from the element and were 1.9to 2.5-cm high. Elements were raised above the former by 5.1 mm. These distances were empirically determined to increase SNR, while retaining high isolation between elements. The RF coil was tested in a Varian 7-T MRI system. Transmit fields were mapped using the method presented by Van de Moortele et al. (2). The required transmit amplitudes and phases for transmit shimming were then calculated to provide maximum transmit efficiency over a 3D ROI covering the entire brain. Two-dimensional multislice gradient-echo images were acquired to measure SNR. The signal was normalized by the standard deviation of pixels in a noise-only scan. To demonstrate the parallel imaging performance, fully sampled gradient echo images were acquired and under-sampling of k-space was performed during post-processing. Two-dimensional geometry-factor maps were then calculated using the SENSE method (3). Results The mean loaded and unloaded Q values of the coil elements were 145 ± 30 and 250 ± 60, respectively, resulting in Q ratios (QU/QL) of 1.3-2.4. The high isolation between coil elements (27 ± 10 dB) increased the effectiveness of RF shimming and allowed for a normalized transmit-field uniformity (std/mean) of 43% over the brain. A representative axial slice of a 3D flip-angle map is shown in Fig. 2. The tight coupling of coil elements to the head reduced the absorbed power during RF transmission (331-μs pulse for a 90° flip angle with a 1-kW hard pulse). During reception, the close proximity of the elements to the head increased SNR in the periphery of the brain, most notably at the top of the head (Fig. 3). The achievable SNR is demonstrated in a slice of a T2-weighted multislice gradient-echo acquisition (Fig. 4). For accelerated imaging, sensitivity profiles of each element are localized beneath their respective shield, resulting in low geometry factors (Fig. 5). Discussion The individually shielded decoupling scheme allowed coil elements to be of arbitrary shape and size and allowed the most efficient use of space on the two-part former. Circumferential shielding around the elements of the conformal coil localized receive sensitivities to below the plane of the shield and created a more rapid decrease in receive sensitivity than an unshielded coil. This caused the SNR to be high in the cortex, while also decreasing the g-factor and the degree of aliasing during SENSE reconstruction. The conformal geometry still achieved sufficient transmit uniformity over the brain. The combination of high cortical SNR and excellent parallel imaging performance make this coil particularly well-suited to functional MRI. References 1. Gilbert et al. MRM 2010; DOI: 10.1002/mrm.22574. 2. Van de Moortele PF et al. Proc. 17 Annual Meeting ISMRM, Honolulu, Hawaii, 2009. p 366. 3. Pruessmann KP et al. MRM 1999; 42:952-962.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A 3 T sodium and proton composite array breast coil.

PURPOSE The objective of this study was to determine whether a sodium phased array would improve sodium breast MRI at 3 T. The secondary objective was to create acceptable proton images with the sodium phased array in place. METHODS A novel composite array for combined proton/sodium 3 T breast MRI is compared with a coil with a single proton and sodium channel. The composite array consists of...

متن کامل

Transceive Stripline Arrays for Ultra High Field Parallel Imaging Applications

G. Adriany, P. Van de Moortele, F. Wiesinger, P. Andersen, J. Strupp, X. Zhang, C. J. Snyder, W. Chen, K. P. Pruessmann, P. Boesiger, J. T. Vaughan, K. Ugurbil Center for MR Research, University of Minnesota Medical School, Minneapolis, United States, Institute for Biomedical Engineering, University and ETH Zurich, Switzerland We present four and eight channel transceive stripline arrays for ul...

متن کامل

A Stripline-like Coil Element Structure for High Field Phased Array Coils and its Application for a 8-channel 9.4T Small Animal Transceive Array

Introduction Ultra-high magnetic field strength, as widely utilised in small animal MRI systems, has advantages of being able to enhance signal-to-noise ratio (SNR) and gain high spectral resolution [1]. However, the homogeneity of B1 field worsens along with the move to higher RF-frequencies. Methods such as RF shimming and transmit SENSE, which require transceive volume-arrays had been propos...

متن کامل

SENSE optimization of a transceive surface coil array for MRI at 4 T.

Parallel imaging (PI) techniques employ the use of multiple radiofrequency (RF) channels to transmit and/or receive the NMR signal. In the current study we use a finite difference time domain (FDTD) method to simulate the electromagnetic fields of a RF coil array operating in transmit-receive (transceive) mode and receive-only mode. Optimization of these configurations for PI is studied as well...

متن کامل

Actively Detunable 8-channel Small Animal Transceive Volume Array for 9.4T MRI systems

Introduction Ultra-high field MRI systems for small animals have seen a rapid development over recent years in a continuous effort to enhance SNR and spectral resolution of MRI images. To circumvent the associated high-field B1 inhomogeneity problem, methods such as RF shimming and Transmit SENSE have been proposed [1-2]. To benefit from the advantages of these techniques, dedicated phased-arra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010