Improved real-time blood flow velocity quantification via application of the Karhunen-Loeve transform for increased signal-to-noise ratio
نویسندگان
چکیده
Background Real-time blood flow velocity quantification requires fast acquisition time and both high spatial and temporal resolution in order to capture clinically relevant features. Multi-coil parallel imaging techniques trade fast realtime cine acquisition with high temporal resolution for lower signal quality. Methods for increasing signal-tonoise ratio (SNR) will allow higher acceleration rates in parallel imaging, leading to faster acquisition times in the context of exercise stress while maintaining signal quality. Increased SNR via the Karhunen-Loeve Transform [1] (KLT) is achieved by decomposing a temporal cine sequence into a series of eigenmodes where the signal of interest is localized in a subset of eigenmodes and eliminating noise-only eigenmodes.
منابع مشابه
Noise Reduction in Real-Time Phase Velocity Images via the Karhunen-Loeve Transform
Introduction: Clinical applications such as exercise stress cardiac MRI require the use of accelerated scan techniques to minimize acquisition time while maintaining image quality. In this context, maintaining sufficient signal-to-noise ratio (SNR) is crucial in order to preserve clinically relevant information. While the combination of echo planar readout and parallel reconstruction successful...
متن کاملDe-noising of dynamic magnetic resonance images by the combined application of wavelet filtering and Karhunen-Loeve Transform (KLT)
Methods The proposed approach combines 2D spatial wavelet filtering with 1D temporal Karhunen-Loeve Transform (KLT). The KLT is first applied to create a series of “eigenimages” in which important signal information is concentrated into only a few eigenimages. Then a 2D spatial wavelet filter is applied to each of the individual eigenimages. An adaptive threshold is used to define the wavelet f...
متن کاملApplication of Single-Frequency Time-Space Filtering Technique for Seismic Ground Roll and Random Noise Attenuation
Time-frequency filtering is an acceptable technique for attenuating noise in 2-D (time-space) and 3-D (time-space-space) reflection seismic data. The common approach for this purpose is transforming each seismic signal from 1-D time domain to a 2-D time-frequency domain and then denoising the signal by a designed filter and finally transforming back the filtered signal to original time domain. ...
متن کاملGeneralized Karhunen-Loeve Transform - IEEE Signal Processing Letters
We present a novel generic tool for data compression and filtering: the generalized Karhunen–Loeve (GKL) transform. The GKL transform minimizes a distance between any given reference and a transformation of some given data where the transform has a predetermined maximum possible rank. The GKL transform is also a generalization of the relative Karhunen–Loeve (RKL) transform by Yamashita and Ogaw...
متن کاملRealtime Cine MRI in Mice with a Single-Shot EPI Sequence and The Karhunen–Loeve Transform
Background and Aims: Mouse models of cardiac disease play a major role in cardiovascular research but are frequently imaged with echocardiography rather than with MRI. While several groups have shown that MRI can image the mouse heart with an unparalleled level of breadth and detail, many in the cardiac research community remain concerned by the complexity and time-consuming nature of cardiac M...
متن کامل