Titanium deposition after peri-implant care with the carbon dioxide laser.
نویسندگان
چکیده
PURPOSE Titanium endosseous implants are becoming increasingly important in dentistry because of their excellent long-term results. However, it has been reported that these implants may lead to higher concentrations of titanium, especially in the lungs and kidneys. The purpose of this study, therefore, was to determine whether CO2 laser-assisted decontamination of exposed implant surfaces is associated with an increase in titanium release. MATERIALS AND METHODS In 6 beagle dogs, a total of 60 implants were placed. After osseointegration and second-stage surgery, peri-implantitis was induced by cotton floss ligatures for 12 weeks. Surgical treatment consisted of granulation tissue removal, including decontamination of the implant surface with 3 different methods. Twenty implants were decontaminated conventionally by an air-powder abrasive for 60 seconds. Another 20 implants were decontaminated by laser treatment alone. The last 20 implants were treated conventionally by air-powder abrasive and then lased. Four months later, fresh tissue samples of various tissues were evaluated by histologic and chemical analysis. RESULTS Quantitative analysis indicated that titanium accumulation could be detected, especially in the spleen, liver, oral mucosa, regional lymph nodes, lung, and kidney in the beagle dog model. DISCUSSION The concentrations found did not exceed those previously reported in the literature. CONCLUSION These results support the hypothesis that CO2 laser-assisted therapy of ailing implants will not result in excessive titanium concentrations in tissues. Accordingly, CO2 lasers appear suitable and safe for peri-implant gingival surgery.
منابع مشابه
Peri-implant care of ailing implants with the carbon dioxide laser.
One of the many applications for which lasers have been proposed in implant dentistry is for the decontamination process. The purposes of this study were to assess possible alterations in titanium implants in vitro and in vivo by use of the carbon dioxide (CO2) laser and to determine whether new bone formation can occur on previously contaminated implants. In vitro, temperature changes at the b...
متن کاملTreatment of peri-implantitis around TiUnite-surface implants using Er:YAG laser microexplosions.
Implant therapy can lead to peri-implantitis, and none of the methods used to treat this inflammatory response have been predictably effective. It is nearly impossible to treat infected surfaces such as TiUnite (a titanium oxide layer) that promote osteoinduction, but finding an effective way to do so is essential. Experiments were conducted to determine the optimum irradiation power for stripp...
متن کاملBone regeneration after peri-implant care with the CO2 laser: a fluorescence microscopy study.
PURPOSE The carbon dioxide (CO2) laser has been shown to be suitable for the treatment of ailing implants. However, comparatively little is known about bone regeneration after laser treatment. Therefore, the purpose of this study was to determine the course of bone regeneration after peri-implant care with the CO2 laser. MATERIALS AND METHODS In 6 beagle dogs, a total of 60 implants and bony ...
متن کاملA Clinical Study Assessing the Influence of Anodized Titanium and Zirconium Dioxide Abutments and Peri-implant Soft Tissue Thickness on the Optical Outcome of Implant-Supported Lithium Disilicate Single Crowns.
PURPOSE To assess the influence of anodized titanium and zirconium dioxide abutments and peri-implant soft tissue thickness on the optical outcome of implant-supported lithium disilicate single crowns. MATERIALS AND METHODS Twenty patients with a missing maxillary single incisor, canine, or first premolar received an endosseous implant after a two-stage surgery protocol. After healing and sof...
متن کاملThermal increment due to ErCr:YSGG and CO2 laser irradiation of different implant surfaces. A pilot study.
OBJECTIVE An evaluation and comparison is made of the thermal increment at different implant surfaces during irradiation with CO2 and ErCr:YSGG lasers. STUDY DESIGN Five threaded and impacted implants with four types of surfaces were inserted in an adult pig rib: two implants with a hydroxyapatite surface (HA) (impacted and threaded, respectively), a machined titanium surface implant (TI mach...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The International journal of oral & maxillofacial implants
دوره 17 5 شماره
صفحات -
تاریخ انتشار 2002