Duplex scanning of normal vertebral arteries.
نویسندگان
چکیده
Vertebral arteries were studied by Duplex scanning in 50 normal subjects. Pretransverse and C6-C5, C5-C4 intertransverse segments were visualized in all cases on both sides; segment C4-C3 was visualized in 100% of the cases on the right side and in 90% on the left; ostium was obtained in 94% of the cases on the right and in 60% on the left. The left vertebral artery was dominant in 48% of the cases while the right vertebral artery was dominant in 14%. Three vertebral arteries were hypoplasic. Duplex scanning was thus found to be an easily performed noninvasive method to study morphological and hemodynamic characteristics of vertebral arteries from their origin to the C4-C3 level.
منابع مشابه
A prospective comparison of duplex sonography vs angiography of the vertebral arteries.
A prospective blind comparison was completed between duplex sonography and angiography of the vertebral arteries. Thirty-two vertebral arteries were studied for direction of flow, degree of origin plaque or stenosis, Doppler characteristics, and vessel size. The vertebral arteries were reliably identified by imaging their course from the subclavian artery into the transverse foramina and by ide...
متن کاملComparison of normal values of Duplex indices of vertebral arteries in young and elderly adults
BACKGROUND Considering the role of aging in brain atrophy and cerebral vascular demand, we carried out this study to clarify the role of aging in duplex indices of vertebral arteries. METHODS From June 2005 to June 2006, 96 volunteers with age range of 20 to 95 years, were evaluated with color doppler for duplex indices of vertebral arteries. Sever hemodynamic stenosis was excluded in all of ...
متن کاملFatal embolic myocardial infarction after systemic thrombolysis for stroke.
213 4 Sturzenegger M, Mattle HP, Rivoir AS, Baumgartner RW: Ultrasound fi ndings in carotid artery dissection: analysis of 43 patients. Neurology 1995; 45: 691–698. 5 Zuber J, Meary E, Meder JF, Mas JL: Magnetic resonance imaging and dynamic CT scan in cervical artery dissections. Stroke 1994; 25: 576– 581. 6 Bui LN, Brant-Zawadzki M, Verghese P, Gillan G: Magnetic resonance angiography of cerv...
متن کاملColor-coded duplex ultrasonography of the origin of the vertebral artery: normal values of flow velocities.
The introduction of color-coded duplex ultrasonography has improved the ease of performing ultrasound investigations of the vertebral arteries. So far, normal values of flow velocities have been reported only for the intertransverse region of the vertebral artery (V2 segments). Atherosclerotic disease at the origin of the vertebral arteries (V0 segment) is frequent and is one of the risk factor...
متن کاملRole of duplex scanning for the detection of atherosclerotic renal artery disease.
To assess the accuracy of renal artery duplex scanning for the purpose of diagnosing atherosclerotic renal artery stenosis, we compared the findings of renal arteriograms to the results of duplex scanning in 41 patients. Using an increase of renal artery peak systolic flow velocity of greater than 180 cm/sec, duplex scanning was able to discriminate normal from diseased renal arteries with a se...