Effects of Different Rotary Files Combined with Different Irrigation Needles on Apically Extruded Debris.

نویسندگان

  • Emel Uzunoglu
  • Sevinc Aktemur Turker
  • Melahat Görduysus
چکیده

The aim of this study was to compare the apically extruded debris associated with ProTaper Next and OneShape Apical files using two different irrigation needles, open-ended and closed-ended (Max-I-Probe). Forty-eight mandibular premolars were assigned to four groups (n=12) as follows: Group PTN-SN: Root canal was prepared with ProTaper Next (PTN) and irrigated with open-ended standard needle; Group PTN-MP: Root canal was prepared with PTN and irrigated with Max-I-Probe; Group OSA-SN: Root canal was prepared with OneShape Apical (OSA) and irrigated with open-ended needle; Group OSA-MP: Root canal was prepared with OSA and irrigated with Max-I-Probe. Debris extruded during instrumentation was collected into pre-weighed Eppendorf tubes. After storage in an incubator at 70 °C for 5 days, the Eppendorf tubes were weighed to obtain the final weight with extruded debris. The difference between pre-and post-debris weights was calculated and statistical analysis was performed using Kruskal-Wallis and Mann-Whitney U tests (p<0.05). No statistically significant difference was observed between files and needles regarding amount of apically extruded debris (p>0.05). OneShape Apical and ProTaper Next resulted in extrusion of debris beyond the apical foramen, regardless of needle tip.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of apically extruded debris between conventional and 2 rotary instrumentation techniques according to the number of applications(An in vitro study)

A comparison of apically extruded debris between conventional and 2 rotary instrumentation techniques according to the number of applications(An in vitro study) Dr. MH. Zarabi* - Dr. H. Djafarzadeh** - Dr. M. Bidar** *- Associate Professor of Endodontics Dept. - Faculty of Dentistry – Mashhad University of Medical Sciences. **- Endodontist. Background and Aim: Various kinds of hand or rotary te...

متن کامل

Comparison of apically extruded debris and instrumentation time using rotary, endodontic handpiece and hand files in primary molar teeth: (In-vitro )

Abstract Background & Aim : This study was aimed to compare the instrumentation time and the amount of debris extruded apically  during root canal preparation using hand files ,Mtwo rotary system and endodontic handpiece  in primary molar teeth. Method & Material : In this experimental study, sixty roots of  primary molars of human teeth were assigned to three groups (for each group, n=20). The...

متن کامل

Comparative Evaluation of the Amount of Debris and Irrigants Extruded Apically by Different Irrigating Needles - An in vitro study

Introduction: The main goal of the successful endodontics is the complete sterilization of the root canal space. During preparation, irrigants and debris such as bacteria, dentin fillings and necrotic debris may be extruded into the periradicular region leading to periapical inflammation and postoperative flare-ups. Several instrument designs and irrigation techniques have been developed to pre...

متن کامل

Evaluation of conventional, protaper hand and protaper rotary instrumentation system for apical extrusion of debris, irrigants and bacteria- An in vitro randomized trial

BACKGROUND Endodontic instrumentation carries the risk of over extrusion of debris and bacteria. The technique used and the type of instrumentation influences this risk. AIM The purpose of this study was to evaluate and compare the K-file, ProTaper hand and ProTaper rotary instrumentation systems for the amount of apically extruded debris, irrigant solution and intracanal bacteria. DESIGN E...

متن کامل

Apically extruded debris with reciprocating single-file and full-sequence rotary instrumentation systems.

INTRODUCTION The purpose of this in vitro study was to assess the amount of apically extruded debris using rotary and reciprocating nickel-titanium instrumentation systems. METHODS Eighty human mandibular central incisors were randomly assigned to 4 groups (n = 20 teeth per group). The root canals were instrumented according to the manufacturers' instructions using the 2 reciprocating single-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian dental journal

دوره 26 4  شماره 

صفحات  -

تاریخ انتشار 2015