Intradiscal pressure monitoring in the cervical spine.
نویسندگان
چکیده
BACKGROUND Discography has been widely used in the lumbar and cervical spine as a diagnostic tool to identify sources of discogenic pain that may be amenable to surgical treatment. Discography in the cervical spine is currently performed without the benefit of pressure monitoring, and corresponding pressure parameters have not been determined. OBJECTIVE The purpose of this study was to develop the framework for intradiscal pressure monitoring in the cervical spine and the basis for a pressure curve that will reflect clinically significant cervical internal disc disruption. We also sought to determine whether there is any pressure increase in adjacent discs during cervical discography that might result in false-positive diagnosis during in-vivo discography. An additional goal was to establish safe upper parameters for infusion volume and intradiscal pressure in the cervical spine. DESIGN Investigation of fresh-frozen discs in the cervical spine. METHODS Investigated were 26 discs in 5 fresh-frozen cadaveric cervical spines aged 45 to 68 with no prior history of cervical spine disease. A T2 MRI was performed on each specimen and radiographically abnormal discs were noted. Pressure-controlled, fluoroscopically guided discography was performed on each level using a right lateral approach. Opening pressure, rupture pressure, volume infused, and location of rupture were recorded. Pressures were simultaneously recorded at each adjacent disc level using additional pressure monitors and identical needle placement. Immediately following discography, CT was performed on each specimen according to the discography protocol. RESULTS Twenty-six discs C2-3 to C7-T1 were grossly intact for evaluation. The median opening pressure was 30 psi (range 14-101 psi). Two discs did not rupture and were pressurized to 367 psi. In 24 discs, the median intradiscal rupture pressure was 40 psi (range 14-171 psi). The median volume infused at rupture was 0.5 ml (range 0.25-1.0 ml). When grouped, the median intradiscal rupture pressure in the C2-3, C3-4, and C7-T1 discs was 53 psi (range 16-171 psi) compared to 36.5 psi (range 14-150 psi) in the C4-5, C5-6, and C6-7 discs (p=0.18). There was no measurable pressure change in any of the 30 adjacent disc levels evaluated. CONCLUSION In the cervical spine, iatrogenic disc injury may be caused at significantly lower pressures and volumes infused than in the lumbar spine. There was no measurable pressure change in any of the adjacent disc levels evaluated at maximum intradiscal pressurization. Further cadaveric testing will be necessary to develop parameters for intradiscal pressure monitoring in the cervical spine.
منابع مشابه
Effect of Spinal Stabilisation on Intradiscal Pressure in Cervical Spine
Introduction The aim of this work was analysis of the stabilisation influence on intradiscal pressure. The investigations were focused on the cervical region of spine, because this is a very common site for injury. It is caused of relatively big range and significant frequency of movements. Some of diseases need the application of the spinal fixator which changed the pressure of the adjacent re...
متن کاملBiomechanical Determination of Distal Level for Fusions across the Cervicothoracic Junction
Study Design In vitro testing. Objective To determine whether long cervical and cervicothoracic fusions increase the intradiscal pressure at the adjacent caudal disk and to determine which thoracic end vertebra causes the least increase in the adjacent-level intradiscal pressure. Methods A bending moment was applied to six cadaveric cervicothoracic spine specimens with intact rib cages. Intradi...
متن کاملIntradiscal Pressure Changes during Manual Cervical Distraction: A Cadaveric Study
The objective of this study was to measure intradiscal pressure (IDP) changes in the lower cervical spine during a manual cervical distraction (MCD) procedure. Incisions were made anteriorly, and pressure transducers were inserted into each nucleus at lower cervical discs. Four skilled doctors of chiropractic (DCs) performed MCD procedure on nine specimens in prone position with contacts at C5 ...
متن کاملEffect of cervical collars on intracranial pressure in patients with head neurotrauma
Trauma patients are at high risk of cervical and associated injuries. The standard protocol includes immobilization of the cervical spine in a polytrauma as it will help to prevent spinal injuries in the prehospital settings. Hard cervical collar (or alternatives) is routinely used until the cervical spine clearance is obtained . In patients with traumatic brain injury avoiding any kind of mane...
متن کاملIntradiscal pressure study of percutaneous disc decompression with nucleoplasty in human cadavers.
STUDY DESIGN Intradiscal pressure was measured after percutaneous disc decompression by nucleoplasty in human cadavers with different degrees of disc degeneration. OBJECTIVES To assess intradiscal pressure change after disc decompression, and to analyze the influence of degeneration on the intradiscal pressure change. SUMMARY OF BACKGROUND DATA Partial removal of the nucleus has been shown ...