Monitoring of partial and full venous outflow obstruction in a porcine flap model using laser speckle contrast imaging.

نویسندگان

  • Johan Zötterman
  • Max Bergkvist
  • Fredrik Iredahl
  • Erik Tesselaar
  • Simon Farnebo
چکیده

BACKGROUND In microsurgery, there is a demand for more reliable methods of post-operative monitoring of free flaps, especially with regard to tissue-threatening obstructions of the feeding arteries and draining veins. In this study, we evaluated laser speckle contrast imaging (LSCI) and laser Doppler flowmetry (LDF) to assess their possibilities to detect partial and full venous outflow obstruction, as well as full arterial occlusion, in a porcine flap model. METHODS Cranial gluteal artery perforator flaps (CGAPs) were raised, and arterial and venous blood flow to and from the flaps was monitored using ultrasonic flow probes. The venous flow was altered with an inflatable cuff to simulate partial and full (50% and 100%) venous obstruction, and arterial flow was completely obstructed using clamps. The flap microcirculation was monitored using LSCI and LDF. RESULTS Both LDF and the LSCI detected significant changes in flap perfusion. After partial (50%) venous occlusion, perfusion decreased from baseline, LSCI: 63.5 ± 12.9 PU (p = 0.01), LDF 31.3 ± 15.7 (p = 0.64). After 100% venous occlusion, a further decrease in perfusion was observed: LSCI 54.6 ± 14.2 PU (p < 0.001) and LDF 16.7 ± 12.8 PU (p < 0.001). After release of the venous cuff, LSCI detected a return of the perfusion to a level slightly, but not significantly, below the baseline level 70.1 ± 11.5 PU (p = 0.39), while the LDF signal returned to a level not significant from the baseline 36.1 ± 17.9 PU (p > 0.99). Perfusion during 100% arterial occlusion decreased significantly as measured with both methods, LSCI: 48.3 ± 7.7 (PU, p < 0.001) and LDF: 8.5 ± 4.0 PU (p < 0.001). During 50% and 100% venous occlusion, LSCI showed a 20% and 26% intersubject variability (CV%), respectively, compared to 50% and 77% for LDF. CONCLUSIONS LSCI offers sensitive and reproducible measurements of flap microcirculation and seems more reliable in detecting decreases in blood perfusion caused by venous obstruction. It also allows for perfusion measurements in a relatively large area of flap tissue. This may be useful in identifying areas of the flap with compromised microcirculation during and after surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous measurement of water flow velocity with fluorescent and speckle imaging technique

The average velocity of water flow has been simultaneously measured with fluorescent and speckle imaging methods. The measured velocities with two methods are in good agreement with each other and it confirms that the speckle imaging method can be used as a confident method to measure the velocity of water flow in a dry leaf. Also the velocity of water flow through thick and thin xylems of a le...

متن کامل

Blood Perfusion in a Full-Thickness Eyelid Flap, Investigated by Laser Doppler Velocimetry, Laser Speckle Contrast Imaging, and Thermography

Purpose: The eyelid is commonly dissected and divided in the process of, for example, blepharotomy, entropion repair, or when preparing a full-thickness eyelid flap to reconstruct a tumor defect. No study has yet been conducted to examine how perfusion in an eyelid is affected by dissection, using modern imaging techniques. Methods: The eyelid was divided with a 10-mm vertical incision, 5 mm fr...

متن کامل

Testing a device to replace the leech for treating venous congestion.

OBJECTIVE To test the effectiveness of a device designed to promote decongestion and tissue survival of a fasciocutaneous flap during 15 hours of complete venous obstruction. METHODS In a porcine model, a 9 x 7-cm fasciocutaneous flap was elevated and the associated veins were clamped, causing complete venous obstruction for 15 hours in 6 control and 6 treatment animals. Up to 3 devices were ...

متن کامل

Vascular Occlusion in a Porcine Flap Model: Effects on Blood Cell Concentration and Oxygenation

Background Venous congestion in skin flaps is difficult to detect. This study evaluated the ability of tissue viability imaging (TiVi) to measure changes in the concentration of red blood cells (CRBC), oxygenation, and heterogeneity during vascular provocations in a porcine fasciocutaneous flap model. Methods In 5 pigs, cranial gluteal artery perforator flaps were raised (8 flaps in 5 pigs). ...

متن کامل

Correcting for motion artifact in handheld laser speckle images.

Laser speckle imaging (LSI) is a wide-field optical technique that enables superficial blood flow quantification. LSI is normally performed in a mounted configuration to decrease the likelihood of motion artifact. However, mounted LSI systems are cumbersome and difficult to transport quickly in a clinical setting for which portability is essential in providing bedside patient care. To address t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of plastic, reconstructive & aesthetic surgery : JPRAS

دوره 69 7  شماره 

صفحات  -

تاریخ انتشار 2016