Technical note: Evaluation of standard ultraviolet absorption ozone monitors in a polluted urban environment

نویسندگان

  • E. J. Dunlea
  • S. C. Herndon
  • D. D. Nelson
  • R. M. Volkamer
  • B. K. Lamb
  • E. J. Allwine
  • M. Grutter
  • C. R. Ramos Villegas
  • M. J. Molina
چکیده

The performance of the EPA Federal Equivalent Method (FEM) technique for monitoring ambient concentrations of O3 via ultraviolet absorption (UV) has been evaluated using data from the Mexico City Metropolitan Area field campaign (MCMA-2003). Comparisons of UV O3 monitors with open path Differential Optical Absorption Spectroscopy (DOAS) and open path Fourier Transform Infrared (FTIR) spectroscopy instruments in two locations revealed average discrepancies in the measured concentrations between +13% to –18%. Good agreement of two separate open path DOAS measurements at one location indicated that spatial and temporal inhomogeneities were not substantially influencing comparisons of the point sampling and open path instruments. The poor agreement between the UV O3 monitors and the open path instruments was attributed to incorrect calibration factors for the UV monitors, although interferences could not be completely ruled out. Applying a linear correction to these calibration factors results in excellent agreement of the UV O3 monitors with the co-located open path measurements; regression slopes of 0.94 to 1.04 and associated R2 values of >0.89. A third UV O3 monitor suffered from large spurious interferences, which were attributed to extinction of UV radiation within the monitor by fine particles (<0.2μm). The overall performance of this Correspondence to: E. J. Dunlea ([email protected]) particular monitor was poor owing to a combination of interferences from a contaminated particle filter and/or ozone scrubber. Suggestions for improved operation practices of these UV O3 monitors and recommendations for future testing are made.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of UV ozone monitors

Technical note: Evaluation of standard ultraviolet absorption ozone monitors in a polluted urban environment E. J. Dunlea ∗ , S. C. Herndon, D. D. Nelson, R. M. Volkamer, B. K. Lamb, E. J. Allwine, M. Grutter, C. R. Ramos Villegas, C. Marquez, S. Blanco, B. Cardenas, C. E. Kolb, L. T. Molina, and M. J. Molina Department of Earth, Atmospheric and Planetary Sciences, Massachusetts Institute of Te...

متن کامل

Comparison of ultraviolet absorbance, chemiluminescence, and DOAS instruments for ambient ozone monitoring.

This paper evaluates the accuracy of ozone measurements made by monitors that determine ozone concentrations in ambient air by UV absorption. These monitors are typically used to measure ozone for the purpose of establishing local compliance to air-quality standards. The study was predicated by the concern that commercially available UV absorbance O3 monitors may be subject to interference from...

متن کامل

Variability in ultraviolet total optical depth during the Southern California Ozone Study (SCOS97)

Formation of photochemical air pollution is governed in part by the solar ultraviolet actinic radiation #ux, but wavelength-resolved measurements of UV radiation in polluted urban atmospheres are rarely available. As part of the 1997 Southern California Ozone Study, cosine weighted solar irradiance was measured continuously at seven UV wavelengths (300, 306, 312, 318, 326, 333 and 368 nm) at tw...

متن کامل

Characteristics and Health Risk of BTEX at Selected Different Microenvironments in an Industrial-Urban Area, Iran

The present study monitors BTEX concentration in outdoor and indoor air of eight different microenvironments during summer 2017 and winter 2018 at Asaloyeh city, Iran's energy capital. It samples BTEX compounds by charcoal tubes, analyzing the samples by means of a gas chromatograph with a flame ionization detector. According to the obtained results, outdoor concentrations of BTEX have been hig...

متن کامل

Characteristics and Health Risk of BTEX at Selected Different Microenvironments in an Industrial-Urban Area, Iran

The present study monitors BTEX concentration in outdoor and indoor air of eight different microenvironments during summer 2017 and winter 2018 at Asaloyeh city, Iran's energy capital. It samples BTEX compounds by charcoal tubes, analyzing the samples by means of a gas chromatograph with a flame ionization detector. According to the obtained results, outdoor concentrations of BTEX have been hig...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006