Primidone analyses: correlation of gas-chromatographic assay with enzyme immunoassay.

نویسندگان

  • L Sun
  • E R Walwick
چکیده

Serum specimens from patients on primidone therapy were assayed by two currently available procedures: a commercially available enzyme immunoassay (EMIT) and a published gas-chromatographic procedure. Both procedures were done with commercially available materials and equipment. Results by the two procedures agreed well, which suggests that the two methods could be used interchangeably. For the 94 specimens studied, the correlation coefficient was 0.98, and the least-squares values of slope and intercept were, respectively, 0.97 and 0.51 mg/liter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anticonvulsants in serum, determined with a fully mechanized enzyme analyzer.

The "EMIT" enzyme immunoassay system (Syva) that involves use of glucose-6-phosphate dehydrogenase (EC 1.1.1.49) as the enzyme label has been adapted to a fully mechanized kinetic enzyme analyzer for analysis of phenobarbital, phenytoin, and primidone. This procedure, compared with the gas-chromatographic procedure of Kupferberg [Clin. Chim. Acta 29, 283 (1970)], gave a weighted regression line...

متن کامل

Monitoring of therapeutic serum concentrations of antiepileptic drugs by a newly developed gas chromatographic procedure and enzyme immunoassay (EMIT): a comparative study.

A gas chromatographic procedure for the simultaneous determination of carbamazepine, phenobarbital and phenytoin using SP 2510 DA as stationary phase is presented. The antiepileptic drugs are determined simultaneously without derivatisation under isothermal conditions by a flame ionisation detector. The gas chromatographic procedure can be easily mechanized. The coefficient of variation for the...

متن کامل

On-line liquid-chromatographic analysis for drugs in serum with the Technicon "FAST-LC" system: performance data for theophylline and for four commonly used anticonvulsants and their metabolites.

We describe a new instrument for use in assay of therpeutic drugs in serum by "high-performance" liquid chromatography, the "FAST-LC" system (Technicon). Serum samples are aspirated directly into the unit, extracted with solvent, and the evaporated and redissolved extract is injected onto a chromatographic column. We illustrate the performance of the system by assays in serum for theophylline a...

متن کامل

Use of saliva in therapeutic drug monitoring.

We measured the concentrations of phenobarbital, phenytoin, primidone, ethosuximide, antipyrine, and caffeine in paired samples of saliva and plasma by gas chromatograph-mass spectrometer-computer (GC/MS/COM) and enzyme immunoassay. Mixed saliva was collected for the antipyrine and caffeine studies, parotid saliva for the phenobarbital, primidone, ethosuximide and phenytoin studies. The saliva/...

متن کامل

Therapeutic monitoring of anticonvulsant drugs: gas-chromatographic simultaneous determination of primidone, phenylethylmalonamide, carbamazepine, and diphenylhydantoin.

We describe a sensitive and precise gas-chromatographic method in which benzylmalonate methylester monoamide is used as the internal standard for the simultaneous determination of primidone, phenylethylmalonamide, carbamazepine, and diphenylhydantoin. The trimethylsilyl derivatives of the anticonvulsants are well separated from each other and from normal serum constituents. The lower limit of d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 22 6  شماره 

صفحات  -

تاریخ انتشار 1976