Meta-analysis and cost comparison of polyethylene glycol lavage versus sodium phosphate for colonoscopy preparation.

نویسندگان

  • C W Hsu
  • T F Imperiale
چکیده

BACKGROUND Although polyethylene glycol lavage solutions are widely used for colonoscopy preparation, evidence suggests that sodium phosphate is better tolerated and has similar efficacy. The purpose of this study was to compare compliance with and efficacy of polyethylene glycol and sodium phosphate using meta-analysis and to compare the cost of colonoscopy with both methods. METHODS We used Medline to identify all randomized controlled trials comparing the two preparations. Study methods were evaluated, and quantitative data were abstracted independently, including inability to complete the preparation and preparation quality, rated as adequate or excellent. A random effects model was used to calculate the pooled relative risk. Direct costs and literature-based probability estimates were used to compare costs. RESULTS Among 1286 subjects from eight colonoscopist-blinded trials, the pooled relative risk of inability to complete the preparation was 0.23 (95% CI [0.18-0.28]) in favor of sodium phosphate. Although the best estimate of the relative risk for an adequate quality preparation revealed therapeutic equivalence (relative risk = 1.06: 95% CI [0.95-1.19]), an excellent quality preparation was more likely with sodium phosphate (relative risk = 1.72: 95% CI [1.16-2.53]). Assuming reexamination rates from published literature of 3% and 8% for sodium phosphate and polyethylene glycol, respectively, direct costs of colonic examination were $465 and $503. There were no clinically important adverse effects with either method. CONCLUSION The results suggest that sodium phosphate is as effective and less costly, with a more easily completed preparation, compared with polyethylene glycol and is the preferred method of preparation for colonoscopy for certain patient subgroups.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of sodium phosphosoda purgative to polyethylene glycol bowel preparations prior to colonoscopy.

BACKGROUND AND OBJECTIVES Successful colonoscopy is contingent upon adequate bowel preparation, which is often achieved using either an oral sodium phosphate preparation or a polyethylene glycol-based preparation. Comparison of the relative performance of these two classes of agents has been assessed only in the context of clinical trials (and with mixed findings). However, efficacy measured in...

متن کامل

Comparison of the Efficacy and Safety of Polyethylene Glycol and Senna Solutions in Colon Preparation before Colonoscopy in Dogs

Objective- The aim of this study was to evaluate the efficacy and safety of senna as an alternative or adjunct to polyethylene glycol (PEG) solution in dogs using colonoscopy and radiography.Design - Experimental study.Animals - 20 adult mongrel healthy dogs.Procedures- Dogs were randomly allocated to receive 1 of 4 different bowel preparation regimens including PEG, senna or ...

متن کامل

A Comparison of 2 L of Polyethylene Glycol and 45 mL of Sodium Phosphate versus 4 L of Polyethylene Glycol for Bowel Cleansing: A Prospective Randomized Trial

BACKGROUND/AIMS Polyethylene glycol (PEG)-based gut lavage solutions are safe and effective, but require the intake of large volumes of fluid. The use of 2 L PEG plus 45 mL sodium phosphate (PEG2 plus NaP) was compared with 4 L PEG (PEG4) for bowel cleansing before colonoscopy. METHODS Patients were randomized to the PEG2 plus NaP group or PEG4 group between January 1, 2009 and March 31, 2010...

متن کامل

Bowel Preparation for Colonoscopy with Sodium Phosphate Solution versus Polyethylene Glycol-Based Lavage: A Multicenter Trial

BACKGROUND Adequate bowel preparation is essential for accurate colonoscopy. Both oral sodium phosphate (NaP) and polyethylene glycol-based lavage (PEG-ELS) are used predominantly as bowel cleansing modalities. NaP has gained popularity due to low drinking volume and lower costs. The purpose of this randomized multicenter observer blinded study was to compare three groups of cleansing (NaP, NaP...

متن کامل

Oral sodium phosphate solution is a superior colonoscopy preparation to polyethylene glycol with bisacodyl.

PURPOSE The aim of this study was to compare the efficacy and patient tolerance of two bowel preparations for colonoscopy. METHODS Three hundred twenty-three consecutive patients undergoing colonoscopy were randomly assigned to receive either oral sodium phosphate, or 2 liters of polyethylene glycol solution preceded by the stimulant laxative bisacodyl. Patients were asked to record the effec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Gastrointestinal endoscopy

دوره 48 3  شماره 

صفحات  -

تاریخ انتشار 1998