Air puff induced corneal vibrations: theoretical simulations and clinical observations.
نویسندگان
چکیده
PURPOSE To investigate air puff induced corneal vibrations and their relationship to the intraocular pressure (IOP), viscoelasticity, mass, and elasticity of the cornea based on theoretical simulations and preliminary clinical observations. METHODS To simulate the corneal movement during air puff deformation, a kinematic viscoelastic corneal model was developed involving the factors of corneal mass, damping coefficient, elasticity, and IOP. Different parameter values were taken to investigate how factors would affect the corneal movements. Two clinical ocular instruments, CorVis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany) and the Ocular Response Analyzer (ORA; Reichert, Inc., Buffalo, NY), were employed to observe the corneal dynamical behaviors. RESULTS Numerical results showed that during the air puff deformation, there would be vibrations along with the corneal deformation, and the damping viscoelastic response of the cornea had the potential to reduce the vibration amplitude. With consistent IOP, the overall vibration amplitude and inward motion depths were smaller with a stiffer cornea. CONCLUSIONS A kinematic viscoelastic model of the cornea is presented to illustrate how the vibrations are associated with factors such as corneal mass, viscoelasticity, and IOP. Also, the predicted corneal vibrations during air puff deformation were confirmed by clinical observation.
منابع مشابه
Corneal Vibrations during Intraocular Pressure Measurement with an Air-Puff Method
Introduction The paper presents a commentary on the method of analysis of corneal vibrations occurring during eye pressure measurements with air-puff tonometers, for example, Corvis. The presented definition and measurement method allow for the analysis of image sequences of eye responses-cornea deformation. In particular, the outer corneal contour and sclera fragments are analysed, and 3D reco...
متن کاملMaterial Properties from Air Puff Corneal Deformation by Numerical Simulations on Model Corneas
OBJECTIVE To validate a new method for reconstructing corneal biomechanical properties from air puff corneal deformation images using hydrogel polymer model corneas and porcine corneas. METHODS Air puff deformation imaging was performed on model eyes with artificial corneas made out of three different hydrogel materials with three different thicknesses and on porcine eyes, at constant intraoc...
متن کاملCorneal Viscoelastic Properties from Finite-Element Analysis of In Vivo Air-Puff Deformation
Biomechanical properties are an excellent health marker of biological tissues, however they are challenging to be measured in-vivo. Non-invasive approaches to assess tissue biomechanics have been suggested, but there is a clear need for more accurate techniques for diagnosis, surgical guidance and treatment evaluation. Recently air-puff systems have been developed to study the dynamic tissue re...
متن کاملContributing factors to corneal deformation in air puff measurements.
PURPOSE Air puff systems have been presented recently to measure corneal biomechanical properties in vivo. In our study we tested the influence of several factors on corneal deformation to an air puff: IOP, corneal rigidity, dehydration, presence of sclera, and in vivo versus in vitro conditions. METHODS We used 14 freshly enucleated porcine eyes and five human donor eyes for in vitro experim...
متن کاملComparison of different intraocular pressure measurement techniques in normal eyes, post surface and post lamellar refractive surgery
BACKGROUND The purpose of this study was to determine the accuracy of intraocular pressure (IOP) measurement after laser in situ keratomileusis (LASIK) or epithelial laser in situ keratomileusis (Epi)-LASIK using Goldmann applanation tonometry, air puff tonometry, ocular response analyzer corneal compensated IOP (ORA IOPcc) and Pentacam corrected IOP. METHODS A prospective comparative clinica...