Clinical indices for orthodontic mini-implants.
نویسنده
چکیده
Orthodontic mini-implants were recently developed and have been widely used in clinics. However, loosening of mini-implants, as well as infection and swelling of mucosal tissue at the placement site, are often observed during orthodontic treatment. Thus, clinical indices are greatly needed for the safe use of orthodontic mini-implants. This article presents information on mini-implants and offers suggestions on indications, placement technique, optimum design, and evaluation of the placement site for mini-implants. The author concludes that 1) mini-implants should be left in the placement site for 3 months before loading to allow for a healing period, which increases the success rate in adolescent patients, 2) placement torque should be considered when tightening mini-implants into bone, as excessively high or low torque results in low stability, 3) mini-implants with optimal screws should be placed in the correct position, and 4) a prepared site should be established in an area with a cortical bone thickness of greater than 1.0 mm, to improve the success rate. Finally, the vector of orthodontic forces in the arrangement with the center of resistance of the entire dental arch should be considered when developing treatment goals.
منابع مشابه
A Mini-review on the Effect of Mini-implants on Contemporary Orthodontic Science
The purpose of this literature review was to screen the valuable published articles regarding to the impacts of mini-implants on orthodontic science, briefly. The searching category was performed on the Pubmed using MeSH words such as "dental (mini) implants, orthodontic anchorage procedures, and orthodontic appliances." After preliminary sketch, they were grouped as follow: Those evaluating (a...
متن کاملGeometrical design characteristics of orthodontic mini-implants predicting maximum insertion torque
OBJECTIVE To determine the unique contribution of geometrical design characteristics of orthodontic mini-implants on maximum insertion torque while controlling for the influence of cortical bone thickness. METHODS Total number of 100 cylindrical orthodontic mini-implants was used. Geometrical design characteristics of ten specimens of ten types of cylindrical self-drilling orthodontic mini-im...
متن کاملMini Implants in Orthodontics – An Overview
Orthodontic treatment observes resistance in areas of desired tooth movement and anchorage sites. Hence, proper orthodontic anchorage preparation is important to ensure predictable tooth movement and negating insufficient reciprocal movement [1]. Understanding each patient’s anchorage requirements is of paramount importance which ensures high-quality care. Unexpected or unintended anchorage los...
متن کاملPrimary stability of orthodontic mini-implants inserted into maxilla and mandible of swine.
OBJECTIVE The objective of this study was to assess the primary stability of different orthodontic mini-implants inserted into different maxillary and mandibular regions of swine. MATERIAL AND METHODS One hundred eighty orthodontic mini-implants produced by 5 different manufacturers, all presenting several shapes, were divided into 5 groups: Mondeal (M), Neodent (N), SIN (S), INP, and Titaniu...
متن کاملPatients' perception of installation, use and results of orthodontic mini-implants.
The purpose of this study was to evaluate patient acceptance and perception of pain with regard to orthodontic mini-implants. The study was conducted on 58 individuals undergoing orthodontic treatment, who had orthodontic mini-implants placed as anchorage devices. Data were collected using a questionnaire containing 6 questions evaluating perception of pain during mini-implant placement and dur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of oral science
دوره 53 4 شماره
صفحات -
تاریخ انتشار 2011