Perforation of the right atrium and the ascending aorta following percutaneous transcatheter atrial septal defect closure.

نویسندگان

  • Jan Vojácek
  • Martin Mates
  • Jana Popelová
  • Petr Pavel
چکیده

Transcatheter closure of secundum atrial septal defect has become an alternative to surgery. We present a patient with hemodynamic collapse secondary to cardiac perforation occurring 36 h after the placement of an Amplatzer Septal Occluder and discuss complications of this kind of device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Integrated Percutaneous Atrial Septal Defect Occlusion and Pulmonary Balloon Valvuloplasty

Introduction: Atrial Septal Defect (ASD) is one of the most common congenital heart diseases during childhood. Today, ASD closure is done by occlutech device via cardiac catheterization. ASD repair with transcatheter technique has shown high closure rate. However, coexistence of severe pulmonary stenosis and large defect in atrial septum is rare. When these two problems coexist, the result is i...

متن کامل

An Experience of a Tertiary Center for 9 Years on Patients with Surgical and Percutaneous Closure of Atrial Septal Defects

Atrial septal defect (ASD) is one of the most common congenital cardiac diseases [1]. ASD accounts for 7-10% of all congenital heart diseases in children and 30-33% in adults. Although ASD usually asymptomatic, it can lead to exercise intolerance, atrial arrhythmia, right ventricular dysfunction, and pulmonary arterial hypertension. Guidelines recommend closure of ASD if right ventricular enlar...

متن کامل

Some immediate hemodynamic consequences of closure of atrial septal defects of the secundum type.

The circumclusion method for surgical closure of atrial septal defects (ASDs) of the secundum type makes it possible, during surgery, to close and reopen the defect as desired. In each of 23 patients the following statistically significant pressure and flow changes were found when the ASD was closed: increasing mean pressures in the ascending aorta (from 74 to 87 mm Hg), left atrium (from 10 to...

متن کامل

Transcatheter Closure of Secundum Atrial Septal Defect Using the Amplatzer Device: Single Center Experience in 140 Patients

In this paper we present our experience with the Amplatzer septal occluder device, employed in 140 patients for percutaneous closure of atrial secundum defect (ASD), from October 2002 to February 2006. The age of patients ranged between 5.3 and 70 years, median 21.9 years. Procedure time ranged between 25 and 240 minutes, median 60 minutes; fluoroscopy time ranged between 3.5 and 45 minutes, me...

متن کامل

Urgent Surgical Intervention for Embolized Cardiac Occluder Devices: A Case Series

Introduction: In this study, we sought to illustrate our experience in urgent surgical management for embolized cardiac septal occlude devices resulting from trans-catheter closure of atrial septal defect and ventricular septal defect. Mathrials and Methods: We retrospectively reviewed four patients aged 2–10 years who underwent urgent surgery due to cardiac septal occluder embolization between...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interactive cardiovascular and thoracic surgery

دوره 4 3  شماره 

صفحات  -

تاریخ انتشار 2005