Application of Genetic Programming for Determination of Wind Loads on Tall Buildings

نویسندگان

  • Divya Aggarwal
  • Naveen Kwatra
چکیده

Tall building can vibrate in both the directions of Along wind and Across wind caused by the flow of wind. Modern Tall buildings designed to satisfy lateral drift requirements, still may oscillate excessively during wind storm. These oscillations can cause some threats to the tall building as buildings with more and more height becomes more vulnerable to oscillate at high speed winds. Sometimes these oscillations may even cause discomfort to the occupants even if it is not in a threatening position for the structural damage. So an accurate assessment of building motion is an essential prerequisite for serviceability. The wind response on tall buildings is generally estimated either through wind tunnel testing or using analytical approach as mentioned in IS8751987, Part-3. However, both these methods are very cumbersome and time consuming. Therefore, in this paper an attempt has been made to estimate the wind response on tall buildings using Genetic Programming in the along wind direction for Long After Body and Short After Body. The database has been developed using the analytical approach as given in IS875-1987, Part-3. The building height, plan dimensions, design wind speed, gust factor and base moment have been used as the parameters for the development of the equations. The Gust Factor and Base Moment thus obtained from Genetic Programming have been thus compared with the analytical values.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Tall Buildings with Bundled Tube System Subjected to Wind and Earthquake loads

At present, the tubular structural systems are mainly used in tall buildings to withstand earthquake loads. Although it is possible to analyse the structure by finite element methods using standard three dimensional programs, the system is generally time-consuming and expensive in the primary design work. In this paper, for the analysis of Framed-Tube systems, a simple method was studied and de...

متن کامل

Analysis of Tall Buildings with Bundled Tube System Subjected to Wind and Earthquake loads

At present, the tubular structural systems are mainly used in tall buildings to withstand earthquake loads. Although it is possible to analyse the structure by finite element methods using standard three dimensional programs, the system is generally time-consuming and expensive in the primary design work. In this paper, for the analysis of Framed-Tube systems, a simple method was studied and de...

متن کامل

Alongwind Static Equivalent Wind Loads and Responses of Tall Buildings. Part I: Unfavorable Distributions of Static Equivalent Wind Loads

Although on the same theoretical basis, the current standards of major countries have set out two evidently different distributions of along-wind static equivalent wind loads, one is the same as the mean wind force and the other is the same as the first mode shape, on tall buildings. In this paper, the fluctuating static equivalent wind load is evaluated as mean, background and resonant compone...

متن کامل

A Simple Approach to Static Analysis of Tall Buildings with a Combined Tube-in-tube and Outrigger-belt Truss System Subjected to Lateral Loading

In this paper, an efficient technique is presented for static analysis of tall buildings with combined tube-in-tube and outrigger-belt truss system while considering shear lag effects. In the process of replacing the discrete structure with an elastically equivalent continuous one, the structure is modeled as two parallel cantilevered flexural-shear beams that are constrained at the outrigger-b...

متن کامل

Interference effects of wind loads on a row of tall buildings

ABSTRACT: We apply CFD to visualize wind flow around a row of three square-plan tall buildings closely arranged in a row. Increase in wind load on the upwind building is observed when wind blows to the row at 30. CFD results show that the interference mechanism is mainly due by strong channeling of wind flow through the building gaps. This leads to highly negative pressures on building walls fa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013