Suitability of Ultra High Frequency Partial Discharge Measurement for Quality Assurance and Testing of Power Transformers

نویسندگان

  • STEFAN TENBOHLEN
  • MARTIN SIEGEL
  • MICHAEL BELTLE
  • MARTIN REUTER
چکیده

Well known reasons for local failures in power transformers are caused by partial discharges (PD) in the electric insulation. Continuous deterioration over time increases the defect which finally can lead to a breakdown of the entire insulation. The importance of PD measurement is accommodated by standardized electrical measurement according to IEC 60270 [1] which is required for acceptance certificates at routine testing. Therefore, the apparent charge QIEC has become an important value for transformer quality. Since a couple of years, alternative measurement methods for PD are used. Originally developed for gas insulated systems [2], [3], ultra high frequency (UHF) measurement found its way into transformer diagnosis over the last years [4]. To become an accepted quality factor, UHF has to be proven a reliable testing method, which can bear up against electrical measurements. Therefore, the general physics of UHF PD has to be considered at first. Ultra-high-frequency antennas measure electromagnetic emissions of PD directly in-oil inside a transformer. It becomes apparent, that UHF measurement usually is advantageous concerning external disturbances. Compared to the electric measurement, the UHF method is robust against external signals [5], which makes it suitable for both, offsite measurement at routine testing under laboratory conditions with low ambient noise and onsite, e.g. after transportation and installation of transformers with usually high noise levels. These considerations make the UHF method interesting as supplement for transformer routine tests. Therefore, a sensor calibration or at least a validation of its sensitivity is required [6] comparable to the electrical measurement. To provide profound knowledge of the equipment, the antenna factor (AF) of the UHF sensor needs to be determined under inside-transformer conditions. This contribution shows the determination of the UHF sensor’s AF using a Gigahertz-Transversal-Electro-Magnetic Setup (GTEM cell). To meet inside-transformer conditions, an oil-filled GTEM cell is required for correct permittivity. Correction factors can then be introduced to minimize measurement errors and to establish better comparability of different UHF sensors. Hence, a standard test setup can be defined.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating the Improvement of Partial Discharge Localization Accuracy Using Frequency Response Assurance Criterion

Partial Discharge (PD) is the most important source of insulation degradation in power transformers. In order to prevent catastrophic failures in transformers, PDs need to be located as soon as possible so that maintenance measures can be taken in time. Due to the structural complexity of windings, locating the PD source inside a transformer winding is not a simple task. In this paper, the effi...

متن کامل

Calibration of UHF Partial Discharge Measurement for Power Transformers And a Comparison to the Calibration of Electrical PD Measurement

The reliability of electrical energy networks depends on the quality and reliability of its electrical equipment, e.g. power transformers. Local failures inside their insulation may lead to catastrophic breakdowns and may cause high outage and penalty costs. To prevent these destroying events, power transformers can be tested on partial discharge (PD) activity before commissioning and monitored...

متن کامل

Partial Discharge Monitoring of Power Transformers by UHF Sensors

The reliability of electrical energy networks depends on both, the quality and the reliability of its electrical equipment, e.g. power transformers. Local failures inside their insulation can lead to breakdowns and hence to high outage and penalty costs. Usually, power transformers are tested on partial discharge (PD) activity before commissioning. UHF PD monitoring can be used to prevent these...

متن کامل

An Intelligent Sensor for the Ultra-High-Frequency Partial Discharge Online Monitoring of Power Transformers

Ultra-high-frequency (UHF) partial discharge (PD) online monitoring is an effective way to inspect potential faults and insulation defects in power transformers. The construction of UHF PD online monitoring system is a challenge because of the high-frequency and wide-frequency band of the UHF PD signal. This paper presents a novel, intelligent sensor for UHF PD online monitoring based on a new ...

متن کامل

Uhf Monitoring of Partial Discharge in Substation Equipment Using a Novel Multi-sensor Cable Loop

This paper describes the development of a partial discharge measurement system that utilises a multiplexed approach to ultra-high-frequency monitoring on many pieces of equipment using a single cable loop connected to only two sampling channels. It is envisioned that the system could be used in partial discharge monitoring of medium voltage metal-enclosed switchgear, or several power transforme...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013