2D and 3D ultrasound assessment of cesarean section scars and its correlation to intraoperative findings
نویسندگان
چکیده
Objective: to investigate the accuracy of 2D and 3D ultrasound in measurement of Cesarean section (CS) scar thickness. Study design: A prospective observational study conducted on 75 pregnant women with previous 1 or 2 CS candidates for elective CS. Evaluation of LUS using 2D and 3D transabdominal and transvaginal ultrasound is then correlated to scar integrity assessed intraoperatively. Results: Five cases had scar dehiscence with incidence of 6.67%. Dehiscence showed a statistically significant difference between women with previous 2 CS and those with previous 1 CS (4 vs. 1 respectively). The best cut-off value for 2D and 3D transabdominal ultrasound was 3.8 and 5.0 mm, with AUC of 0.737and 0.824, yielding a sensitivity of 60% and 100%, specificity of 91.4% and 62.86% respectively .The best cut-off value for 2D and 3D transvaginal ultrasound was 2.0 and 1.9 mm with AUC of 0.931 and 0.974 with sensitivity of 100% and 100%, specificity of 65.71% and 87.14% respectively. Conclusion: ultrasound is a reliable method for measuring the LUS thickness and scar integrity in patients with previous CS. The use of transvaginal 3D ultrasound in measuring the muscular layer thickness of LUS is the most reliable route with high sensitivity and specificity.
منابع مشابه
Two and Three Dimensional Ultrasound Assessment of Cesarean Section Scars in Pregnant Women with Previous One or Two Cesarean Section and Its Correlation to Intraoperative Findings
The risk of uterine scar dehiscence and uterine rupture is inversely related to the lower uterine segment (LUS) thickness as measured by ultrasound. Three dimensional ultrasound can increase the reliability of ultrasound in prediction of scar dehiscence. Transvaginal three dimensional ultrasound measurement of the muscular layer thickness of the lower uterine segment seems to be the most reliab...
متن کاملThe Role of Three Dimensional Transvaginal Ultrasound in Detection of Intrauterine Device Displacement in Post Caesarean Section: A Case Report
Intrauterine Devices (IUDs) are used as an efficient and inexpensive method of contracep¬tion. Contraceptive efficacy depends on the intrauterine location of IUD and intrauterine displacement of the IUD leads to decreased contraceptive efficacy. Expulsion of IUD and its penetration into myometrium is one of the complications of IUD. In cases where IUDs are not detected by ultrasound method, in ...
متن کاملTransvaginal Ultrasonographic Assessment of Post-Cesarean Section Scar Defects
Objective: To evaluate post cesarean section scars by transvaginal ultrasonography (TVS) and analyze its relationship to menstrual disturbances. Study Design: Cross sectional study. Settings: Kasr El-Aini Obstetrics and Gynecology Department, Ultrasound Unit. Patients: 60 non-pregnant women with regular cycles and a history of one or more cesarean sections at least 6 months from last cesarean s...
متن کاملUltrasonographic Volumetry of the Canine Thyroid Gland: A Comparison of 2D, 3D Ultrasonography and Real Gland Volume
Objective: to compare the estimated thyroid volume, as determined by two-dimensional (2D) and three-dimensional (3D) ultrasonography, with real volume. Design: Descriptive Study Animals: A total of 7 mixed breed dogs Procedures: On 2D ultrasound, the thyroid volume is estimated by the ellipsoid equation and on 3D ultrasound; it is estimated by outlining the boundaries of the thyroid lobe in ...
متن کاملVisibility and measurement of cesarean section scars in pregnancy: a reproducibility study.
OBJECTIVES To evaluate the visibility of cesarean section (CS) scars by transvaginal sonography (TVS) in pregnant women, to apply a standardized approach for measuring CS scars and to test its reproducibility throughout the course of pregnancy. METHODS In this observational cohort study, 320 consecutive pregnant women with a previous cesarean delivery were examined to assess scar visibility b...
متن کامل