Diagnosis of middle cerebral artery occlusion with transcranial color-coded real-time sonography.
نویسندگان
چکیده
PURPOSE To determine the usefulness of transcranial color-coded real-time sonography in detecting occlusion of the horizontal portion of the middle cerebral artery. METHODS Using transcranial color-coded real-time sonography, we measured the end-diastolic flow velocity with incident angle correction and the side-to-side ratio of the end-diastolic flow velocity (the end-diastolic ratio) in both middle cerebral arteries in 44 patients with or without occlusive disease. Cerebral angiography was carried out in all patients before or within 1 week after sonography. The subjects included 4 patients with unilateral stenosis of the extracranial internal carotid artery > or = 75%; ICS group), 6 with unilateral occlusion of the extracranial internal carotid (ICO group), 6 with occlusion of the horizontal portion of the middle cerebral artery (M1 group), and 28 without stenotic (< 75%) lesions in the internal carotid artery (control group). RESULTS In the control group, the end-diastolic flow velocity was 40.4 +/- 16.8 cm/s (mean +/- SD) and the end-diastolic ratio was 1.28 +/- 0.27. In the ICS and ICO groups, the end-diastolic flow velocities on the affected side and the end-diastolic ratios were 33.4 +/- 9.0 cm/s and 1.35 +/- 0.24, and 29.6 +/- 10.2 cm/s and 1.67 +/- 0.58, respectively. In the M1 group, the end-diastolic flow velocity (16.7 +/- 4.29 cm/s) on the occluded side was significantly lower than that in the other groups. The end-diastolic ratio (3.53 +/- 1.47) in the M1 group was significantly higher than that in the other groups. CONCLUSION The M1 group could be easily distinguished from the other groups on the basis of the end-diastolic ratio. Measurement of the end-diastolic flow velocity and the end-diastolic ratios in the middle cerebral artery by means of transcranial color-coded real-time sonography may help to identify an occlusion in the horizontal portion of the middle cerebral artery.
منابع مشابه
Comparison of transcranial power Doppler and contrast-enhanced color-coded sonography in the identification of intracranial arteries.
Power-based transcranial color-coded sonography and contrast-enhanced transcranial color-coded sonography are ultrasonographic techniques that allow improved visualization of vascular structures. The present study was designed to investigate and compare the diagnostic capacity and applicability of both methods in the assessment of intracranial vessels of the circle of Willis (33 patients) and t...
متن کاملContrast-enhanced transcranial color-coded sonography in acute hemispheric brain infarction.
PURPOSE The aim of the present study was to investigate the diagnostic potential of contrast-enhanced transcranial color-coded real-time sonography (CE-TCCS) in otherwise ultrasound-refractory acute stroke patients with an ischemia in the territory of the middle cerebral artery (MCA). Furthermore, correlations of CE-TCCS findings with clinical, angiographic, and CT results were investigated. ...
متن کاملDiagnosis of middle cerebral artery stenosis by transcranial color-coded real-time sonography.
BACKGROUND & PURPOSE This study was performed to determine the usefulness of transcranial color-coded real-time sonography (TCCS) in detecting stenosis in the horizontal portion of the middle cerebral artery (MCA). METHODS Using TCCS and the incident angle correction technique, we measured the peak-systolic flow velocity in bilateral MCAs in 45 consecutive patients in whom cerebral angiograph...
متن کاملTranscranial color-coded real-time sonographic criteria for occlusion of the middle cerebral artery in acute ischemic stroke.
BACKGROUND AND PURPOSE Transcranial color-coded real-time sonography (TCCS) is a useful tool to evaluate disease of the middle cerebral artery (MCA). This study was undertaken to identify TCCS criteria for the diagnosis of MCA stem and MCA branch occlusions. METHODS TCCS and digital subtraction angiography were performed in 55 consecutive patients with acute stroke: 10 with MCA stem occlusion...
متن کاملBenefit of echocontrast-enhanced transcranial color-coded duplex ultrasound in the assessment of intracranial collateral pathways.
BACKGROUND AND PURPOSE Although clinically important, proper assessment of intracranial arterial collateral pathways by transcranial color-coded duplex sonography (TCCD) in patients with internal carotid artery (ICA) high-grade stenosis or occlusion is occasionally made difficult by an insufficient temporal bone window, an unfavorable insonation angle, or low flow velocity or volume. In these c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 17 5 شماره
صفحات -
تاریخ انتشار 1996