Purpose:The Monte Carlo calculation algorithm in the MultiPlan (Accuray, Palo Alto, CA) treatment planning system used for CyberKnife (Accuray) robotic radiosurgery requires in-air measurements. In this study, results were compared for the impact of build-up caps using a diode
ثبت نشده
چکیده
ID: 18837 Title: Improved Collimator Scattering Factor (Sc) Measurements for Small Fields Using Build-Up Caps in Robotic Radiosurgery Purpose:The Monte Carlo calculation algorithm in the MultiPlan (Accuray, Palo Alto, CA) treatment planning system used for CyberKnife (Accuray) robotic radiosurgery requires in-air measurements. In this study, results were compared for the impact of build-up caps using a diode detector for small field in-air measurements. Methods:Two acrylic caps custom-made for the SFD diode detector (IBA, Germany) of two thicknesses were compared against free-in-air measurements. The 1.5 and 5 cm thicknesses correspond to Dmax and a depth beyond the range of electron contamination, respectively. A Blue Phantom (IBA) was used to position the diode 80 cm SAD. Measurements were made for all 12 fixed cones ranging from 5 to 60 mm. Results:For the 5 mm cone, there is a 15.6% and 20.0% difference in the Sc factor between the 1.5 cm and 5 cm buildup caps, respectively, versus the free-in-air measurement. For the 7.5 mm cone, the difference is 6.3% and 10.4% for the 1.5 cm and 5 cm buildup caps, respectively, versus the free-in-air measurement. While generally decreasing, the Sc factor for either buildup cap does not agree within 2% to free-in-air measurements until the cone used is larger than 40 mm. Overall, the two buildup caps yield similar Sc factors and the differences observed are attributed to electron contamination. Conclusions:The Monte Carlo calculation algorithm used by the CyberKnife planning manual does not refer to any build-up caps. This study has shown that, particularly for small fields, there are large differences in Sc factors measured with and without buildup caps. In general, for fields smaller than 10 mm, build-up caps should be carefully chosen, especially in commissioning data.
منابع مشابه
SU-E-T-176: Improved Collimator Scattering Factor (Sc) Measurements for Small Fields Using Build-Up Caps in Robotic Radiosurgery.
PURPOSE The Monte Carlo calculation algorithm in the MultiPlan (Accuray, Palo Alto, CA) treatment planning system used for CyberKnife (Accuray) robotic radiosurgery requires in-air measurements. In this study, results were compared for the impact of build-up caps using a diode detector for small field in-air measurements. METHODS Two acrylic caps custom-made for the SFD diode detector (IBA, G...
متن کاملInfluence of smoothing algorithms in Monte Carlo dose calculations of cyberknife treatment plans: a lung phantom study.
AIM The Monte Carlo dose calculation algorithm yields accurate dose distributions in heterogeneous media and interfaces. The Monte Carlo calculation algorithm provided in the Multiplan Cyberknife treatment planning system (Accuray, Sunnyvale, CA, USA) has five different dose-smoothing algorithms in it. As the principle of smoothing of these algorithms is different, they can produce a disparity ...
متن کاملStereotactic robotic body radiotherapy for patients with unresectable hepatic oligometastases
Objectives: To evaluate the feasibility, efficacy and toxicity of robotic stereotactic body radiotherapy for the treatment of unresectable hepatic oligometastases. Methods: Between 09/2010 and 06/2015, 43 consecutive patients (19 female, 24 male, median age at treatment: 69.8 ; range, 43-83 years) with up to three synchronous or metachronous hepatic oligometastases were referred for Cyberknife ...
متن کاملStaged Radiosurgical Ablation for Choroid Melanoma: A Case Report with Emphasis on the Role of Patient Preparation, Treatment Planning, and Precision of Delivery
The aim of reporting this case of choroid melanoma of the left eye is to introduce the in-house-designed treatment planning protocol for fractionated radiosurgical ablation of an intraocular lesion. This is a clinical case with emphasis on treatment preparation and delivery using the Accuray CyberKnife Robotic Radiosurgery System (Accuray, Sunnyvale, CA, USA) for a patient immobilized with a he...
متن کاملDosimetric Evaluation of Dose calculation algorithms of Monaco Treatment Planning System in the heterogeneities area
Introduction: In radiation therapy, the accuracy of dose calculations by a treatment planning system (TPS) is important to achieve tumor control and to spare normal tissue. Treatment planning system calculations in the heterogeneous situation may present significant inaccuracies. In this study, three different dose calculation algorithms, pencil beam (PB), collapsed cone (CC), ...
متن کامل