Analysis of metallothioneins by means of capillary electrophoresis coupled to electrospray mass spectrometry with sheathless interfacing.
نویسندگان
چکیده
Capillary electrophoresis (CE) coupled to electrospray mass spectrometry via sheathless interfacing has been applied to the analysis of mammalian metallothionein (MT) extracts. In a rabbit-liver extract, four (MT-2C, MT-2A, MT-2D and MT-2E) out of six known MT sub-isoforms were unambiguously identified under three CE-resolved peaks. A fourth peak was found to contain MT-1A and/or MT-2B, whose molecular masses differ by only 1 Da. Traces of non-N-acetylated MT-2D and MT-2E were observed in a fifth, minor peak. In a rat-liver extract, both MT-1 and MT-2 were resolved and identified. Non-N-acetylated MT-2 was also identified in a resolved, minor peak. Minimum detectable amounts of MTs have been estimated to be approximately 0.6 fmol per sub-isoform.
منابع مشابه
CESI-MS of Intact Proteins
There is a growing need for selective and sensitive analytical tools for the characterization of intact proteins. The effective coupling of capillary electrophoresis and electrospray ionization timeof-fl ight mass spectrometry (CE-ESI-TOF-MS) may offer an attractive option by providing both the separation and detection required to distinguish structurally-related protein species [1,2]. In order...
متن کاملSheathless Capillary Electrophoresis-Tandem Mass Spectrometry for Top-Down Characterization of Pyrococcus furiosus Proteins on a Proteome Scale
Intact protein analysis via top-down mass spectrometry (MS) provides the unique capability of fully characterizing protein isoforms and combinatorial post-translational modifications (PTMs) compared to the bottom-up MS approach. Front-end protein separation poses a challenge for analyzing complex mixtures of intact proteins on a proteomic scale. Here we applied capillary electrophoresis (CE) th...
متن کاملA colloidal graphite-coated emitter for sheathless capillary electrophoresis/nanoelectrospray ionization mass spectrometry.
A colloidal graphite-coated emitter is introduced for sheathless capillary electrophoresis/nanoelectrospray ionization time-of-flight mass spectrometry (CE/ESI-TOFMS). The conductive coating can be produced by brushing the capillary tip to construct a fine layer of 2-propanol-based colloidal graphite. The fabrication involves a single step and requires less than 2 min. Full cure properties deve...
متن کاملA soft on-column metal coating procedure for robust sheathless electrospray emitters used in capillary electrophoresis-mass spectrometry.
An on-column metal coating procedure was developed for sheathless electrospray emitters, based on Justus von Liebig's electroless silver mirror reaction followed by electrochemical deposition of gold onto the silver layer. The coating procedure is straightforward, mild, inexpensive, and can be performed with standard laboratory equipment. A long-term (600 h) stability investigation of the condu...
متن کاملSheathless capillary electrophoresis/electrospray mass spectrometry using a carbon-coated fused-silica capillary
A simple procedure was developed for preparing a carbon-coated fused-silica capillary for use in sheathless capillary electrophoresis/electrospray mass spectrometry (CE/ESI-MS). The tapered capillary tip was smeared with a marker pen before coating with carbon using a soft pencil. The layer from the ink of the marker pen was critical to the preparation of the carbon-coated capillary. The fabric...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Rapid communications in mass spectrometry : RCM
دوره 13 6 شماره
صفحات -
تاریخ انتشار 1999