Calibration Issues for the MMA

نویسنده

  • Mark Holdaway
چکیده

The precision imaging to be attained by the MMA will be achieved through accurate calibration. The types of calibration are summarized in Table 3.1. Single Antenna Calibration Employed Calibration strategies will be developed and implemented on the NRAO 12m telescope, and the OVRO and BIMA arrays. The principal goals to be achieved by the end of the MMA Design and Development (D&D) Phase are to demonstrate radiometric phase correction at 22 GHz, including demonstration of correction algorithms at OVRO and BIMA; and to demonstrate improved instrumental amplitude calibration. The principal milestones required to achieve this goal are shown in Table 3.2.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Residual Methylmethacrylate Monomerin Denture Base Resins by Gas Chromatography

Acrylic base resins are widely used in orthopedics and dental surgery. It is generally accepted that due to the incomplete conversion of methyl methacrylate (MMA) monomer to the polymer form during polymerization of the resin, some MMA monomers remain in the hardened material. MMA monomer has been reported to cause abnormalities or lesions in several organs of animals. Study of the literatures ...

متن کامل

Determination of Residual Methylmethacrylate Monomerin Denture Base Resins by Gas Chromatography

Acrylic base resins are widely used in orthopedics and dental surgery. It is generally accepted that due to the incomplete conversion of methyl methacrylate (MMA) monomer to the polymer form during polymerization of the resin, some MMA monomers remain in the hardened material. MMA monomer has been reported to cause abnormalities or lesions in several organs of animals. Study of the literatures ...

متن کامل

MMA Memo 211 Accurate Amplitude and Flux

The 10% amplitude calibration accuracy achievable with the current standard calibration techniques may be suucient to produce images with dynamic range of 10 3 , but achieving a dynamic range of 10 4 or higher with the MMA requires better than 1 percent accuracy in amplitude calibration. A self-calibration technique may be applied to improve images, but it may not be possible in all cases. Ther...

متن کامل

Comparison of serum and plasma methylmalonic acid measurements in 13 laboratories: An international study.

BACKGROUND Detection of cobalamin deficiency is increasingly important, and methylmalonic acid (MMA) appears to be a useful marker. Information on interlaboratory variation and on methodological differences for MMA in serum and plasma is limited. METHODS Using gas chromatography/mass spectrometry, 13 laboratories participated in a 2-day analysis of 8 serum and 11 EDTA-plasma specimens. Result...

متن کامل

External quality assessment of urinary methylmalonic acid quantification - results of a pilot study.

Measurement of methylmalonic acid (MMA) is recognised as a useful tool in the diagnostic work-up of suspected cobalamin deficiency (1). Increased concentrations of MMA in both serum and urine are indicative of cobalamin deficiency at the tissue level. MMA measurement in serum as the sample material is convenient from a logistic point of view, since analysis can be performed using residual sampl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998