A Few Remarks of additional shielding on Electron Linac Radiation Oncology Facilities --- Measurements and Analysis on Angular Distribution of Dose Rate around Targets Bombarded by 18, 25, 34 MeV Electrons

نویسندگان

  • Kazuaki Kosako
  • Koji Oishi
  • Takashi Nakamura
چکیده

Dose rate measurements have been performed around the cupper, tungsten and aluminum targets bombarded by 18, 25 and 34 MeV electrons. The detectors were set at 500 mm from the target and the angles were 0, 30, 60, 90 and 120 degrees in the direction to the beam line. Three kinds of detectors were applied for the measurements, miniature ionization chamber and glass dosimeter for photons, and CR-39 for neutrons, respectively. The measured results were compared with calculated ones by using the Monte Carlo calculation code MCNP5. Very good agreements were obtained in the case of ionization chamber and glass dosimeter, when the influence of electrons scattered by the target were involved in the calculation. However, some discrepancies for the dose rate of neutrons were observed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Benchmarking of Siemens Linac in Electron Modes: 8-14 MeV Electron Beams

Introduction: Radiation therapy using electron beams is a promising method due to its physical dose distribution. Monte Carlo (MC) code is the best and most accurate technique for forespeaking the distribution of dose in radiation treatment of patients.Materials and Methods: We report an MC simulation of a linac head and depth dose on central axis, along with profile calculations. The purpose o...

متن کامل

The influence of neutron contamination on pacemaker in photon beam radiotherapy by LINAC using the Monte Carlo method

Introduction: In radiation therapy with high-energy photon beams (E > 7 MeV) neutrons are generated mainly in LINACs head thorough (γ, n) interactions. These neutrons affect the shielding requirements in radiation therapy rooms. According to the protocol TG-34, photon absorbed dose of 10Gy can cause permanent damage to the pacemaker and the dose of 2Gy can make minor changes in...

متن کامل

Secondary Particles Produced by Hadron Therapy

Introduction Use of hadron therapy as an advanced radiotherapy technique is increasing. In this method, secondary particles are produced through primary beam interactions with the beam-transport system and the patient’s body. In this study, Monte Carlo simulations were employed to determine the dose of produced secondary particles, particularly neutrons during treatment. Materials and Methods I...

متن کامل

On Presentation of Optimal Treatment Plan in Radiotherapy of Parotid Cancer: A Comparison of Nine Techniques in Three Dimensional Conformal Radiation Therapy

Introduction: Today, radiotherapy combined with surgery in the treatment of parotid tumors widely are used specially for high grade parotid tumors. One of concern and challenge issue of radiotherapy is that the treatment of these tumors with irregular surface due to the presence of external ear and region of different physical electron density (air cavities, dense bone, soft t...

متن کامل

Evaluation of the Effects of Different Filters and Helium Bag on the Reduction of Electron Contamination in Photon Beam of Neptun Linac

Introduction:  Skin  sparing  is  one  of  the  most  desirable  characteristics  of  high  energy  photon  beams. However, the photons emerging from the target of linacs are contaminated by secondary  electrons  as  a  result  of  their  interactions  with  air,  collimators,  flattening  filter  and  any  other  objects in their path. This phenomenon tends to increase the skin dose received b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008