Inter‐ and intrafractional setup errors and baseline shifts of fiducial markers in patients with liver tumors receiving free‐breathing postoperative radiation analyzed by cone‐beam computed tomography
نویسندگان
چکیده
This study was to evaluate the interfractional and intrafractional setup errors and baseline shifts of golden fiducial markers in patients receiving postoperative radio- therapy (RT) using cone-beam computed tomography (CBCT) in order to calculate PTV margins for patients with liver cancer. Twelve patients with liver tumors under- went postoperative RT. CBCT images were acquired before and after the treatment. Off-line vertebral body match and fiducial marker match were used, respectively. The results of vertebral body match represented the setup errors of the patients, while the results of fiducial marker match represented the absolute position errors of the target volume. Baseline shifts of the target volume were calculated as the absolute target position errors minus setup errors. A total of 12 patients with 214 acquisi- tions of CBCTs were analyzed. Both Σ and σ of setup errors and baseline shifts in left-right (L/R), superior-inferior (S/I), and anterior-posterior(A/P) directions were calculated, including interfractional and intrafractional uncertainties. Planning target volume (PTV) margins were calculated according to margin = 2.5Σ + 0.7σ. Margins of 1.8 mm, 3.8 mm, and 1.4 mm in L/R, S/I, and A/P directions are needed to compensate intrafractional errors when daily online CBCT correction is used. When CBCT correction with no action level (NAL) protocol is used, PTV margin should be 2.6 mm, 5.9 mm, and 2.6 mm in L/R, S/I, and A/P directions. Margins of 5.5 mm, 14.6 mm, and 7.2 mm were needed to compensate the baseline shifts when electronic portal imaging devices (EPID) or CBCT with bone match is used for online correction of setup error.
منابع مشابه
Tumor motion changes in stereotactic body radiotherapy for liver tumors: an evaluation based on four-dimensional cone-beam computed tomography and fiducial markers
BACKGROUND For stereotactic body radiation therapy (SBRT) of liver tumors, tumor motion induced by respiration must be taken into account in planning and treatment. We evaluated whether liver tumor motion at the planning simulation represents liver tumor motion during SBRT, and estimated inter- and intrafractional tumor motion changes in patients undergoing liver SBRT. METHODS Ten patients un...
متن کاملUsability assessment of cone beam computed tomography with a full-fan mode bowtie filter compared to that with a half-fan mode bowtie filter
Background: In intensity modulated radiation therapy, cone beam computed tomography (CT) has been used to evaluate patients prior to treatment. This study conducted a comparative evaluation of the image reconstruction ability of the clinically used half-fan bowtie filter and the full-fan bowtie filter. Materals and Methods: A CT simulation marker was inserted inside a human phantom, and the pel...
متن کاملComparison of localization performance with implanted fiducial markers and cone-beam computed tomography for on-line image-guided radiotherapy of the prostate.
PURPOSE The aim of this work was to assess the accuracy of kilovoltage (kV) cone-beam computed tomography (CBCT)-based setup corrections as compared with orthogonal megavoltage (MV) portal image-based corrections for patients undergoing external-beam radiotherapy of the prostate. METHODS AND MATERIALS Daily cone-beam CT volumetric images were acquired after setup for patients with three intra...
متن کاملHypofractionated radiotherapy for lung tumors with online cone beam CT guidance and active breathing control
BACKGROUND To study the set-up errors, PTV margin and toxicity of cone beam CT (CBCT) guided hypofractionated radiotherapy with active breathing control (ABC) for patients with non-small cell lung cancer (NSCLC) or metastatic tumors in lung. METHODS 32 tumors in 20 patients were treated. Based on the location of tumor, dose per fraction given to tumor was divided into three groups: 12 Gy, 8 G...
متن کاملLiver motion during cone beam computed tomography guided stereotactic body radiation therapy.
PURPOSE Understanding motion characteristics of liver such as, interfractional and intrafractional motion variability, difference in motion within different locations in the organ, and their complex relationship with the breathing cycles are particularly important for image-guided liver SBRT. The purpose of this study was to investigate such motion characteristics based on fiducial markers trac...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 15 شماره
صفحات -
تاریخ انتشار 2014