Non-melanoma skin cancer treated with HDR Valencia applicator: clinical outcomes
نویسندگان
چکیده
PURPOSE Radiotherapy (RT) has played a significant role in treating non melanoma skin cancer (NMSC). High-dose-rate brachytherapy (HDR-BT) approaches have a paramount relevance due to their adaptability, patient protection, and variable dose fractionation schedules. Several innovative applicators have been introduced to the brachytherapy community. The Valencia applicator is a new superficial device that improves the dose distribution compared with the Leipzig applicator. The purpose of this work is to assess the tumor control, cosmesis, and toxicity in patients with NMSC treated with the Valencia applicator and a new regimen of hypofractionation. MATERIAL AND METHODS From January 2008 to March 2010, 32 patients with 45 NMSC lesions were treated with the Valencia applicator in the Hospital La Fe. The gross tumor volume was visually assessed, but the tumor depth was evaluated using ultrasound imaging. All lesions for the selected cases were limited to 4 mm depth. The prescription dose was 42 Gy in 6 or 7 fractions (biologically effective dose [BED] ≈ 70 Gy), delivered twice a week. RESULTS Ninety-eight percent of the lesions were locally controlled at 47 months from treatment. Ninety-three percent of patients were out at least 36 months from treatment. The treatment was well tolerated in all cases. The highest skin toxicity was grade 1 RTOG/EORTC, having resolved with topical treatment at 4 weeks in all but one case which required 2 months. There were no grade 2 or higher late adverse events. CONCLUSIONS In patients with superficial basal cell carcinoma lesions less than 25 mm in maximum diameter, HDRBT treatment with the Valencia applicator using a hypofractionated regimen provides excellent results, for both cosmetic and local control at a minimum of 3 years follow-up. Moreover, the shorter hypofractionated regimen facilitates compliance, which is very relevant for the elderly patients in our series. Valencia applicators offer a simple, safe, quick, and attractive nonsurgical treatment option.
منابع مشابه
Non-melanoma skin cancer treated with high-dose-rate brachytherapy and Valencia applicator in elderly patients: a retrospective case series
PURPOSE The incidence of non-melanoma skin cancer (NMSC) has been increasing over the past 30 years. Basal cell carcinoma and squamous cell carcinoma are the two most common subtypes of NMSC. The aim of this study was to estimate tumour control, toxicity, and aesthetic events in elderly patients treated with high-dose-rate (HDR) brachytherapy (BT) using Valencia applicator. MATERIAL AND METHO...
متن کاملThe initial experience of electronic brachytherapy for the treatment of non-melanoma skin cancer
BACKGROUND Millions of people are diagnosed with non-melanoma skin cancers (NMSC) worldwide each year. While surgical approaches are the standard treatment, some patients are appropriate candidates for radiation therapy for NMSC. High dose rate (HDR) brachytherapy using surface applicators has shown efficacy in the treatment of NMSC and shortens the radiation treatment schedule by using a conde...
متن کاملDosimetric characteristics of a new unit for electronic skin brachytherapy
PURPOSE Brachytherapy with radioactive high dose rate (HDR) (192)Ir source is applied to small skin cancer lesions, using surface applicators, i.e. Leipzig or Valencia type. New developments in the field of radiotherapy for skin cancer include electronic brachytherapy. This technique involves the placement of an HDR X-ray source close to the skin, therefore combining the benefits of brachythera...
متن کاملNon-melanoma skin cancer treated with high-dose-rate brachytherapy: a review of literature
PURPOSE The incidence of non-melanoma skin cancer (NMSC) has been increasing over the past 30 years. There are different treatment options and surgical excision is the most frequent treatment due to its low rates of recurrence. Radiotherapy is an effective alternative of surgery, and brachytherapy (BT) might be a better therapeutic option due to high radiation dose concentration to the tumor wi...
متن کاملCommissioning and quality assurance procedures for the HDR Valencia skin applicators
The Valencia applicators (Nucletron, an Elekta company, Elekta AB, Stockholm, Sweden) are cup-shaped tungsten applicators with a flattening filter used to collimate the radiation produced by a high-dose-rate (HDR) 192Ir source, and provide a homogeneous absorbed dose at a given depth. This beam quality provides a good option for the treatment of skin lesions at shallow depth (3-4 mm). The user ...
متن کامل