Intra-observer and inter-observer repeatability of ocular surface interferometer in measuring lipid layer thickness
نویسندگان
چکیده
BACKGROUND Tear lipid morphology is important for normal tear function. Recently, there have been clinical studies using interferometry to assess lipid layer thickness (LLT). The aim of the study is to examine the repeatability of a commercially available interferometer. METHODS Two observers measured LLT in twenty Asian subjects (20 eyes) using an interferometer (LipiView® ocular surface interferometer, TearScience Inc, Morrisville, NC). Dry eye symptoms, tear break up time (TBUT) and corneal fluorescein staining were also prospectively evaluated. RESULTS Data for 20 participants are presented for either right or left eye (randomly selected). The mean LLT ± standard deviation of these participants was 53.53 ± 14.59 nm. When a single observer repeated the imaging on the same day, the coefficient of repeatability was 16 nm and the 95% limits of agreement were between -11 nm and 18 nm. When a different observer repeated the scan, the coefficient of repeatability was 13 nm and limits of agreement were -9 nm and 16 nm. LLT was not significantly associated with TBUT, presence of any corneal staining in any corneal zones, or symptomatic status. CONCLUSION With the repeatability of measurements being known, the significance of LLT changes measured by this interferometer may be better interpreted. In this small Asian study, the LLT was lower than previously reported studies.
منابع مشابه
بررسی میزان خطا در تعیین نقاط سفالومتریک آنالیز Delaire
The architectural and structural analysis of Delaire was developed to evaluate complex craniofacial structures without relating the individual to a so-called normal or average group. This analysis is especially valuable in two regards: first, this analysis is based upon mutual balance of the cranial and facial structures; second, statistical averages are avoided. But , the p...
متن کاملRepeatability and Reproducibility of Eight Macular Intra-Retinal Layer Thicknesses Determined by an Automated Segmentation Algorithm Using Two SD-OCT Instruments
PURPOSE To evaluate the repeatability, reproducibility, and agreement of thickness profile measurements of eight intra-retinal layers determined by an automated algorithm applied to optical coherence tomography (OCT) images from two different instruments. METHODS Twenty normal subjects (12 males, 8 females; 24 to 32 years old) were enrolled. Imaging was performed with a custom built ultra-hig...
متن کاملAssessment of central corneal thickness and corneal endothelial morphology using ultrasound pachymetry, non-contact specular microscopy, and Confoscan 4 confocal microscopy
BACKGROUND The aim was to compare the repeatability, reproducibility and inherent precision of ultrasound pachymetry (USP), noncontact specular microscopy (SP-2000P) and the Confoscan 4 confocal microscope (z-ring CS4) in measuring endothelial cell density (ECD), coefficient of variation of cell size (CV), and central corneal thickness (CCT) in normal eyes. METHODS In this prospective study, ...
متن کاملComparison of Double and Single Leg Weight-Bearing Radiography in Determining Knee Alignment
Background: Knee malalignment is an important modifiable cause of osteoarthritis (OA). Surgical therapeutic procedures depend on proper knee alignment assessment. The purpose of this study was to compare knee alignment parameters between double and single leg weight-bearing radiographs and to evaluate the reproducibility of inter- and intra-observer measurements. Methods: One hundred eight p...
متن کاملReliability of Measuring Subcutaneous Fat Tissue Thickness Using Ultrasound in Non-Athletic Young Adults.
BACKGROUND Obesity is a major health burden worldwide. A method of assessing uncompressed subcutaneous adipose tissue thickness (USATT) using ultrasound is widely used in sports medicine. However, studies on the reliability of the method in non-athletic people are lacking. We aim to determine the reliability of the human observer in measuring the USATT in non-athletic people. MATERIAL AND MET...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 15 شماره
صفحات -
تاریخ انتشار 2015