Phase Contrast Microradiography of Mouse Lung Using Synchrotron X-ray: Correlation with Optical Microscopy
نویسندگان
چکیده
PURPOSE The purpose of this study is to evaluate the feasibility of phase contrast X-ray microtomography and microradiography, using a polychromatic synchrotron X-ray, for analysis of the mouse lung microstructure. MATERIALS AND METHODS Normal mice were used for experiments. Some of the mouse lungs were prepared by the lung fixation-inflation method. The resulting sponge-like inflated lung samples were used for microtomography. The remaining mouse lungs were cut into 10 microm sections and were used for microradiography and optical microscopic correlation. The experiments on mouse lung samples were performed at the 7B2 beamline of the Pohang Light Source in Korea. RESULTS Phase contrast X-ray microtomography of inflated lung samples showed individual alveolar structure on 3-D reconstruction. Phase contrast microradiographs of thin lung samples showed microstructure of lung, such as alveoli and bronchioles, and were well correlated with optical microscopic images. CONCLUSIONS The results indicate that the phase contrast X-ray microtomography and microradiography using polychromatic synchrotron X-ray is feasible for evaluation of microstructure of the lung.
منابع مشابه
X-ray Phase Contrast Imaging of Cell Isolation with Super-Paramagnetic Microbeads
Super-paramagnetic microbeads are widely used for cell isolation. Evaluation of the binding affinity of microbeads to cells using optical microscopy has been limited by its small scope. Here, magnetic property of microbeads was first investigated by using synchrotron radiation (SR) in-line x-ray phase contrast imaging (PCI). The cell line mouse LLC (Lewis lung carcinoma) was selected for cell a...
متن کاملA Review of the Applications of Synchrotron Radiation in Archaeological Sciences
The scientific research regarding investigation, characterization and protection of the archeological specimens is manifested through a notable participation of multidisciplinary subjects and experts, scientists and archeometrists. One of the main principals which are considered by archaeometrists in the study of the precious specimens is the utilizing nondestructive methods. As an example, in ...
متن کاملMultiple-beam X-ray interferometry for phase-contrast microtomography.
The first successful operation of an X-ray interferometer under conditions of non-planar three-beam diffraction for phase-contrast X-ray microtomography is reported. Intrinsic phase differences of the reflections used cancel from the three-dimensional phase image of the specimen. With simultaneous hkl and hkl reflections of a synchrotron radiation beam in a side-by-side geometry, the size of th...
متن کاملX-Ray Phase-Contrast CT of a Pancreatic Ductal Adenocarcinoma Mouse Model
To explore the potential of grating-based x-ray phase-contrast computed tomography (CT) for preclinical research, a genetically engineered mouse model of pancreatic ductal adenocarcinoma (PDAC) was investigated. One ex-vivo mouse specimen was scanned with different grating-based phase-contrast CT imaging setups covering two different settings: i) high-resolution synchrotron radiation (SR) imagi...
متن کاملOptical klystron FEL scheme for x-ray coherent harmonic generation at ISLF storage ring
The possibility of inserting an optical klystron on the storage ring of an Iranian Light Source Facility as a Synchrotron Radiation Free electron Laser for coherence harmonic generation in the soft x-ray spectrum has been studied. The study has been performed using the 3D FEL simulation code GENESIS 1.3 and in accordance with the available characteristic parameters of ISLF. Different potential ...
متن کامل