An ultra high resolution, electro-optical framing camera for reconnaissance and other applications

نویسندگان

  • Bruce Mathews
  • Lockheed Martin Fairchild
چکیده

A framing camera incorporating an ultra high resolution CCD detector array comprised of 9,216 x 9,216 pixels is discussed. The detector array measures 8 x 8 centimeters and has been scaled to be fabricated in one piece on a 5inch diameter silicon wafer. Pixel size is 8.75 x 8.75 microns which gives 57 lp/mm resolution. The detector array features a two frame per second readout capability which allows collection of stereo imagery from very high V/H platforms. Image Motion Compensation is achieved by operating the frame readout clocks during the exposure interval in typical TDI fashion. The high geometric accuracy of pixel placement on the array yields a camera suitable for mapping, reconnaissance, space and astronomy applications. In this paper, measured detector array performance, detector array yield and overall camera performance are presented.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electro-Optical Design of Imaging Payload for a Remote Sensing Satellite

Remote sensing using small spacecraft arising from multi-objective economic activity problems is getting more and more developed. These satellites require very accurate pointing to specific locations of interest, with high reliability and small latency. The space borne imaging systems always attempted to achieve the highest ground resolution possible with the available technology at the given t...

متن کامل

Image Enhancement of the Super Resolution Channel (src) of the Mars Express Hrsc Experiment

The SRC or Super Resolution Channel is the framing imaging subsystem of the HRSC experiment on the ESA Mars Express spacecraft, designed to show high-resolution detail within the broad swath of the HRSC push-broom camera. It has a separate optical system (focal length 980 mm, f/11) and a 1024x1024 CCD detector, achieving a ground pixel size of 2.3 m from an altitude of 250 km [1]. By December 2...

متن کامل

Ultra-Fast All-Optical Symmetry 4×2 Encoder Based on Interface Effect in 2D Photonic Crystal

This paper deals with the design and simulation of all-optical 4×2 encoderusing the wave interference effect in photonic crystals. By producing 4 opticalwaveguides as input and two waveguides as output, the given structure was designed.The size of the designed structure is 133.9 μm2. The given all-optical encoder has acontrast ratio of 13.2 dB, the response time of 0.45 ...

متن کامل

OPTIMEX: Measurement of Detonation Front Curvature with a Passive Fiber Optical System

The ability of a newly developed independent passive optical system OPTIMEX to measure the detonation front curvature is demonstrated on charges of pressed explosive A-IX-1 (RDX/ceresin-stearin mixture with 95/5 wt.%). The charges, with length to diameter ratios of from one to four, were prepared from cylinders with diameters of 21 mm, 30 mm, 40 mm and 50 mm pressed to a density of 1.66 g/cm3. ...

متن کامل

Optical coherence techniques for plasma spectroscopy „invited..

A new electro-optically modulated optical solid-state ~MOSS! spectrometer has been constructed for high temporal resolution measurement of the coherence of line radiation from plasmas. The instrument is an electro-optically modulated fixed delay polarization interferometer, or Fourier transform spectrometer. It has high light throughput compared with conventional grating based instruments of co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003