Optimization of Improved Motion-sensitized Driven-equilibrium (iMSDE) blood suppression for carotid artery wall imaging

نویسندگان

  • Chengcheng Zhu
  • Martin J Graves
  • Jianmin Yuan
  • Umar Sadat
  • Jonathan H Gillard
  • Andrew J Patterson
چکیده

BACKGROUND Improved motion-sensitized driven-equilibrium (iMSDE) preparations have been successfully used in carotid artery wall imaging to achieve blood suppression, but it causes notable signal loss, mostly due to inherent T2 decay, eddy current effects and B1 + inhomogeneity. In this study, we investigate the signal to noise ratio (SNR) and blood suppression performance of iMSDE using composite RF pulses and sinusoidal gradients. Optimized first moment (m1) values for iMSDE prepared T1- and T2- weighted (T1- and T2-w) imaging are presented. METHODS Twelve healthy volunteers and six patients with carotid artery disease underwent iMSDE and double inversion recovery (DIR) prepared T1- and T2-w fast spin echo (FSE) MRI of the carotid arteries. Modified iMSDE module using composite RF pulses and sinusoidal gradients were evaluated with a range of m1. SNR of adjacent muscle, vessel wall and the lumen were reported. The optimized iMSDE module was also tested in a 3D variable flip angle FSE (CUBE) acquisition. RESULTS The SNR of muscle was highest using sinusoidal gradients, and the relative improvement over the trapezoidal gradient increased with higher m1 (p<0.001). Optimal SNR was observed using an iMSDE preparation scheme containing two 180° composite pulses and standard 90° and -90° pulses (p=0.151). iMSDE produced better blood suppression relative to DIR preparations even with a small m1 of 487 mT*ms2/m (p<0.001). In T1-w iMSDE, there was a SNR decrease and an increased T2 weighting with increasing m1. In T2-w iMSDE, by matching the effective echo time (TE), the SNR was equivalent when m1 was <= 1518 mT*ms2/m, however, higher m1 values (2278 - 3108 mT*ms2/m) reduced the SNR. In the patient study, iMSDE improved blood suppression but reduced vessel wall CNR efficiency in both T1-w and T2-w imaging. iMSDE also effectively suppressed residual flow artifacts in the CUBE acquisition. CONCLUSIONS iMSDE preparation achieved better blood suppression than DIR preparation with reduced vessel wall CNR efficiency in T1-w and T2-w images. The optimized m1s are 487 mT*ms2/m for T1-w imaging and 1518 mT*ms2/m for T2-w imaging. Composite 180° refocusing pulses and sinusoidal gradients improve SNR performance. iMSDE further improves the inherent blood suppression of CUBE.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time-Efficient Black Blood RCA Wall Imaging at 3T Using Improved Motion Sensitized Driven Equilibrium (iMSDE): Feasibility and Reproducibility

BACKGROUND The aim of this study was to explore the feasibility and reproducibility of a time-efficient coronary vessel wall measurement approach using an improved motion-sensitized driven equilibrium (iMSDE) pulse sequence. METHODOLOGY In this study, the iMSDE pulse sequence was first optimized and then applied on a group of healthy volunteers (N = 10) to evaluate its feasibility of vessel w...

متن کامل

Assessment of improved motion-sensitized driven equilibrium (iMSDE) for multi-contrast vessel wall screening.

PURPOSE We assessed the improved motion-sensitized driven equilibrium (iMSDE) technique for multiple contrast 3-dimensional vessel wall imaging at 3T. METHODS Carotid images were obtained using iMSDE combined with turbo field echo (iMSDE-TFE) and conventional double inversion-recovery turbo spin-echo (DIR-TSE) in 5 healthy adult subjects. The tissue signal-to-noise efficiency (SNReff), SNR di...

متن کامل

[Optimization of black blood CINE for mobile plaque].

For examining carotid plaque, black blood (BB) magnetic resonance (MR) imaging can diagnose plaque components based on MR signals. Dynamic images for evaluating the mobility of carotid plaque may also be useful as an adjunct to the diagnosis of carotid plaque. The aim of this study was to find optimal parameters for dynamic images using the black blood technique (BB CINE). All experiments were ...

متن کامل

Clinical Assessment of motion sensitized driven equilibrium (MSDE) prepared T1W 3D vessel wall imaging at 3.0T for soft plaque screening

INTRODUCTION: Motion sensitized driven equilibrium (MSDE) prepared sequence has been proposed for fast black-blood vessel wall imaging (1, 2). Moreover, for detection of different kinds of plaques at the carotid artery wall, MSDE prepared 3D gradient echo sequence, optimized both for T1 and T2 contrasts, was proposed (3). This method allows wider anatomical coverage in short acquisition time co...

متن کامل

Assessment of motion sensitized driven equilibrium (MSDE) improvement for whole brain application

INTRODUCTION: Contrast-Enhancement (CE) magnetic resonance imaging (MRI) is a promising modality for screening of brain metastasis (1). Paramagnetic contrast media exhibits metastatic lesions as hyper-intensities on T1W images. Because blood vessels are also enhanced, it is important to suppress the blood signal in order to reduce potential misdiagnoses (2). Although this can be achieved by a 3...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2014