In Vitro Testing of Femoral Impaction Grafting With Porous Titanium Particles: A Pilot Study

نویسندگان

  • René Aquarius
  • Luc Walschot
  • Pieter Buma
  • Berend Willem Schreurs
  • Nico Verdonschot
چکیده

The disadvantages of allografts to restore femoral bone defects during revision hip surgery have led to the search for alternative materials. We investigated the feasibility of using porous titanium particles and posed the following questions: (1) Is it possible to create a high-quality femoral graft of porous titanium particles in terms of graft thickness, cement thickness, and cement penetration? (2) Does this titanium particle graft layer provide initial stability when a femoral cemented stem is implanted in it? (3) What sizes of particles are released from the porous titanium particles during impaction and subsequent cyclic loading of the reconstruction? We simulated cemented revision reconstructions with titanium particles in seven composite femurs loaded for 300,000 cycles and measured stem subsidence. Particle release from the titanium particle grafts was analyzed during impaction and loading. Impacted titanium particles formed a highly interlocked graft layer. We observed limited cement penetration into the titanium particle graft. A total mean subsidence of 1.04 mm was observed after 300,000 cycles. Most particles released during impaction were in the phagocytable range (< 10 microm). There was no detectable particle release during loading. Based on the data, we believe titanium particles are a promising alternative for allografts. However, animal testing is warranted to investigate the biologic effect of small-particle release.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

• Porous Titanium Particles in Cemented Impaction Grafting Hip Revision Arthroplasty: Pre-Clinical Results

Introduction: Bone impaction grafting (BIG) is a surgical technique for the restoration of bone stock loss in revision total hip arthroplasty (rTHA) by impaction of allograft bone particles (BoP) into the bony defect. BoP are considered to be the gold standard, although many alternative materials have been developed, most of them being ceramic based. Important properties of these synthetic mate...

متن کامل

The effect of impaction and a bioceramic coating on bone ingrowth in porous titanium particles

BACKGROUND AND PURPOSE Porous titanium (Ti) particles can be impacted like cancellous allograft bone particles, and may therefore be used as bone substitute in impaction grafting. We evaluated the effect of impaction and of a thin silicated biphasic calcium phosphate coating on osteoconduction by Ti particles. METHODS The bone conduction chamber of Aspenberg was used in goats and filled with ...

متن کامل

Impaction bone grafting of the acetabulum at hip revision using a mix of bone chips and a biphasic porous ceramic bone graft substitute

BACKGROUND AND PURPOSE One of the greatest problems of revision hip arthroplasty is dealing with lost bone stock. Good results have been obtained with impaction grafting of allograft bone. However, there have been problems of infection, reproducibility, antigenicity, stability, availability of bone, and cost. Thus, alternatives to allograft have been sought. BoneSave is a biphasic porous cerami...

متن کامل

Porous titanium particles for acetabular reconstruction in total hip replacement show extensive bony armoring after 15 weeks

BACKGROUND AND PURPOSE The bone impaction grafting technique restores bone defects in total hip replacement. Porous titanium particles (TiPs) are deformable, like bone particles, and offer better primary stability. We addressed the following questions in this animal study: are impacted TiPs osteoconductive under loaded conditions; do released micro-particles accelerate wear; and are systemic ti...

متن کامل

Defining the impaction frequency and threshold force required for femoral impaction grafting in revision hip arthroplasty

BACKGROUND AND PURPOSE The two most common complications of femoral impaction bone grafting are femoral fracture and massive implant subsidence. We investigated fracture forces and implant subsidence rates in embalmed human femurs undergoing impaction grafting. The study consisted of two arms, the first examining the force at which femoral fracture occurs in the embalmed human femur, and the se...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical Orthopaedics and Related Research

دوره 467  شماره 

صفحات  -