A study on the reliability of measuring dynamic balance ability using a smartphone
نویسندگان
چکیده
[Purpose] Evaluation of the reliability of smartphones as measuring equipment for dynamic balance ability was the goal of this study. [Subjects and Methods] Subjects were 30 healthy young students in their 20s. The first and second rounds of measurements were taken at a one-day interval to confirm test-retest reliability. The subjects stood on the footboard of the Biodex Balance System. Balance was measured using a smart phone. [Results] Acceleration rates corresponding to subjects with open eyes were 2.7 ± 2.2 (first measurement) and 3.3 ± 1.5 (second measurement), and the interclass correlation coefficient ICC (1,1) was 0.8. Acceleration rates corresponding to subjects with closed eyes were 4.1 ± 2.4 (first measurement) and 4.5 ± 1.8 (second measurement), and the ICC (1,1) was 0.9. Gyroscope rates corresponding to subjects with open eyes were 1.7 ± 1.2 (first measurement) and 2.3 ± 1.5 (second measurement), and the ICC (1,1) was 0.7. Gyroscope rates corresponding to subjects with closed eyes were 6.7 ± 2.4 (first measurement) and 6.6 ± 2.3 (second measurement), and the ICC (1,1) was 0.6. [Conclusion] The results of this study suggest that smartphones have sufficient potential as measuring equipment for dynamic balance ability.
منابع مشابه
The Reliability and Concurrent Validity of Digital Inclinometer, Smartphone Applications, and the Cervical Range of Motion Device for Measuring the Cervical Range of Motion
Objectives: Changes in the Range of Motion (ROM) are essential criteria in determining the severity of spinal disorders and could be effective in predicting pain progression. Instruments to measure the ROM are costly and unavailable in most therapy settings. While there is a tendency in therapists to use their smartphones instead, there is no report to measure the suitability of smartphones to ...
متن کاملReliability Assessment of Functional Balance Tests in Endomorph Healthy Women 24-34 years old
Introduction and Purpose: Due to the importance of functional balance tests assessment with emphasis on parameters influencing the balance including somatotype, this study undertaken to determine the reliability of functional balance tests (static, semi-dynamic and dynamic) in endomorphe healthy women within 24-34 years old. Methodology: 25 female endomorphe with the average and standard dev...
متن کاملThe Effect of Feedback based on Inherent and Incremental Ability Theories on Dynamic Balance in Middle-aged Women
The aim of this study was to examine the effect of inherent and incremental ability theories feedback on dynamic balance in middle-aged women. 29 middle-aged women (age: 50-60) randomly assigned into two groups (inherent ability= 15 subjects, and incremental ability= 14 subjects). Both groups after the dynamic balance pretest (Timed Up and Go) received different instructions feedback. Immediate...
متن کاملImpact of mini trampoline exercise on dynamic balance in old women
Introduction: An increase of age may cause an obvious effect on physiologic systems which are involved in the balance function. It is estimated that 6% of health care costs are spent on unintentional injuries in elderly population. The aim of this study is to analyze the effect of Mini-trampoline training on dynamic balance abilities in the elderly subjects. Methods: During a clinical tri...
متن کاملDeveloping and Validating a New Wireless Wearable Device for Balance Measurement in Sport and Clinical Setting
One of the new clinical techniques to assess the lower body parameters is the wearable ultrasonic sensors. The device which can measure the static and dynamic balance abilities in sport and clinical setting by the traveled signals of ultrasonic transmitter and receiver between two feet was developed and validated. The new device consisted of a pressure gauge and a digital centimeter indicator a...
متن کامل