Electron Cloud Measurements in Fermilab Main Injector and Recycler

نویسندگان

  • J. Eldred
  • M. Backfish
  • C. Y. Tan
  • R. Zwaska
چکیده

This conference paper presents a series of electron cloud measurements in the Fermilab Main Injector and Recycler. A new instability was observed in the Recycler in July 2014 that generates a fast transverse excitation in the first high intensity batch to be injected. Microwave measurements of electron cloud in the Recycler show a corresponding dependence on the batch injection pattern. These electron cloud measurements are compared to those made with a retarding field analyzer (RFA) installed in a field-free region of the Recycler in November. RFAs are also used in the Main Injector to evaluate the performance of beampipe coatings for the mitigation of electron cloud. Contamination from an unexpected vacuum leak revealed a potential vulnerability in the amorphous carbon beampipe coating. The diamond-like carbon coating, in contrast, reduced the electron cloud signal to 1% of that measured in uncoated stainless steel beampipe.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Beam Manipulation and Compression Using Broadband Rf Systems in the Fermilab Main Injector and Recycler

A novel method for beam manipulation, compression, and stacking using a broad band RF system in circular accelerators is described. The method uses a series of linear voltage ramps in combination with moving barrier pulses to azimuthally compress, expand, or cog the beam. Beam manipulations can be accomplished rapidly and, in principle, without emittance growth. The general principle of the met...

متن کامل

Measurement of Electron Cloud Density with Microwaves in the Fermilab Main Injector*

Electron cloud density in the Fermilab Main Injector was measured by observing microwave transmission along the vacuum tube. Presence of the electron cloud reduces the velocity of the microwave signal. Both frequency and time domain methods reveal relative cloud density and time evolution. The effect of beam time structure is clearly evident. The accelerator magnetic field effects the distribut...

متن کامل

Fermilab Accelerator R&d Program towards Intensity Frontier Accelerators : Status and Progress*

The 2014 P5 report indicated the accelerator-based neutrino and rare decay physics research as a centrepiece of the US domestic HEP program at Fermilab. Operation, upgrade and development of the accelerators for the nearterm and longer-term particle physics program at the Intensity Frontier face formidable challenges. Here we discuss key elements of the accelerator physics and technology R&D pr...

متن کامل

Analysis and Measurements of Emittance Dilution from Vacuum Windows in the Fermilab Recycler Transfer Lines*

Round-trip beam transfers between the Fermilab Main Injector and Recycler (antiproton accumulator) have been plagued by an emittance dilution of about a factor of 2 with corresponding beam loss. The source of the large dilution was traced to two Ti vacuum windows, one installed in each of the two transfer lines that connect the machines for beam injection/extraction. The dilution can be account...

متن کامل

Experience with Magnetic Shielding of a Large Scale Accelerator

It is not unusual to place multiple accelerators in a common enclosure to save on civil construction costs. This often complicates operations, especially if accelerators are affecting each other. At Fermilab, the influence of a rapidly cycling Main Injector (MI) synchrotron on an antiproton storage ring (Recycler), placed in a common tunnel, was initially found to be unacceptable for a reliable...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015