The ABCs of accurate volumetric measurement of cerebral hematoma.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Both initial hematoma volume and hematoma growth are independent predictors of clinical outcomes and mortality among intracerebral hemorrhage patients. The purpose of this study was to evaluate the accuracy of different computed tomography image acquisition protocols and hematoma volume measurement techniques. METHODS We used plastic and cadaveric phantoms to determine the accuracy of different volumetric measurement techniques. We performed both axial and spiral computed tomography scans with 0.75-, 1.5-, 3.0-, and 4.5-mm-thick transverse sections (with no gap). Different measurement techniques (planimetry, ABC/2, and 3D rendering) and different window width/level settings (I, 150/50 versus II, 587/-321) were used to assess generated errors in volumetric calculations. RESULTS Both axial and spiral computed tomography scans yielded similar percent errors for different slice thicknesses and different measurement techniques. Comparison of different measurement techniques revealed a significant difference in measurement error only from the ABC/2 method as compared with 3D-rendering measurements (P<0.0001). The overall measurement error according to the ABC/2 method was further increased by approximately 8% for irregularly shaped hematomas (P=0.0004). A significant percent difference in measurement error was observed between window width/levels I and II for both planimetry (mean difference across all thicknesses, 1.91 ± 3.78, P=0.004) and Analyze software (mean difference across all thicknesses, 6.92 ± 7.29, P<0.0001) methods. CONCLUSIONS A better understanding of the limitations that may affect measurement of hematoma volume is crucial in the assessment of hematoma volume, which is considered an independent marker of clinical outcome.
منابع مشابه
Feasibility of using Medical Imaging Interaction Toolkit in volumetric studies to accurate diagnosing of vascular emboli by Extended NURBS-based Cardiac-Torso phantom
Introduction: Important complications of venous thromboembolism (VTE) are a longer hospital stay, readmission, recurrence of the emboli, complications of anticoagulant therapy and death in a sever condition. In present study, the volume measurement accuracy of the medical imaging interaction toolkit (MITK) software on determining VTE in computed tomography images was evaluated....
متن کاملMagnitude of Hematoma Volume Measurement Error in Intracerebral Hemorrhage.
BACKGROUND AND PURPOSE Limiting intracerebral hemorrhage (ICH) and intraventricular hemorrhage (IVH) expansion is a common target for acute ICH studies and, therefore, accurate measurement of hematoma volumes is required. We investigated the amount of hematoma volume difference between computed tomography scans that can be considered as measurement error. METHODS Five raters performed baselin...
متن کاملComparison of the ABC/2 estimation technique to computer-assisted volumetric analysis of intraparenchymal and subdural hematomas complicating the GUSTO-1 trial.
BACKGROUND AND PURPOSE The volume of an intracerebral hemorrhage has been shown to be an important independent predictor of mortality in several reports. A technique for estimating hematoma volume, known as the ABC/2 method, has been proven a reliable, simple bedside technique for the volume measurement of intraparenchymal intracerebral hemorrhage. Subdural hematomas also carry a significant mo...
متن کاملInvestigation of the Correlation between Scalp Hematoma and Cranial Fractures and Intracranial Lesions in Children Presenting with Minor Head Trauma
Introduction: Minor head trauma is one of the common causes of pediatric reference to emergency ward. This study investigated the correlation between scalp hematoma,cranial fractures and intracranial lesions in children presenting with minor head traumata. Methods: This was a descriptive cross-sectional study. The data gathering were done in 2016-17. All children under 18 years of age (933 ind...
متن کاملMeasurement of Volumetric and Viscometric Properties of Binary Mixtures of Methyl Tert-butyl Ether (MTBE) + 1-Alcohol from 293.15 to 308.15 K and at Atmospheric Pressure
Densities and viscosities of binary mixtures of methyl tert-butyl ether (MTBE) with 1-alkanols include 1-butanol, or +1-pentanol, or +1-hexanol, or +1-heptanol were measured as a function of composition from 293.15 to 308.15 K at atmospheric pressure. The temperatures studied were 293.15, 298.15, 303.15 and 308.15 K. The experimental results have been used to calculate the viscosity de...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Stroke
دوره 42 6 شماره
صفحات -
تاریخ انتشار 2011