Pentax-AWS videolaryngoscope for nasotracheal intubation in patients with difficult airways
نویسندگان
چکیده
Corresponding author: Keon-Sik Kim, M.D., Department of Anesthesiology and Pain Medicine, Kyung Hee University Medical Center, Hoegidong, Dongdaemun-gu, Seoul 130-702, Korea. Tel: 82-2-958-8591, Fax: 82-2-958-8580, E-mail: [email protected] This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http:// creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. CC It is difficult to intubate with Macintosh laryngoscope or fiberoptic bronchoscope in patients with narrow oropharyngeal space, deformed oro-pharyngeal-larynx structures, or restricted neck movement. The Pentax-AWS (AWS, Pentax, Tokyo, Japan) (Fig. 1) is a rigid video laryngoscope for intubation, which consists of a disposable transparent blade (Pblade), a camera, and a monitor. A target mark on the monitor suggests the tracheal tube direction of advance, facilitating easy and accurate intubation. We report on the use of the AWS for nasotracheal intubation in two patients with oropharyngeal lesions, in whom Macintosh laryngoscopic and fiberoptic bronchoscopic intubation had failed. The first patient was a 56-yr-old man (163 cm, 64 kg), who was presented with right facial palsy after a right radical parotidectomy about 8 months ago due to an adenocystic parotid cancer. He had limited neck motion, which was expected due to the radiation therapy and prior neck dissection. For tensor fascia lata sling operation, anesthesia was induced with a bolus of propofol (2 mg/kg) and rocuronium (0.8 mg/kg) intravenously. We tried to insert a 7.0 mm ID nasal RAE tracheal tube through the nose, because the nasotracheal intubation offers more convenience for surgical maneuvering. Nasotracheal intubation with Macintosh laryngoscope was attempted, but visualization of the glottis was impossible (Cormak and Lehane [C/L] grade 3). Secondly, with passing the fiberoptic bronchoscope (LFTP, Olympus, Fukushima, Japan) (diameter; 5.0 mm) through the nasal RAE tube, we tried to locate the tip of the fiberoptic bronchoscope to the glottis. But it was impossible to see the glottis mainly due to swelling in the pharynx. Next, nasal intubation, with the AWS, was attempted. With the nasal tube in place, the AWS was easily inserted orally with its tip toward the glottic side of the epiglottis, and a full view of the glottis was displayed on the videoscreen. The Magill forceps could not be used because when the AWS was in the mouth, there was not enough space to manipulate a Magill forceps. Also, without any introducer, the tube was smoothly advanced into the trachea without any difficulty by external pressure to the neck for targeting symbol mark. Nasotracheal intubation using the AWS was achieved within 20 seconds. The second patient was a 71-yr-old woman (153 cm, 48 kg), who was scheduled with an operation for a wide excision of
منابع مشابه
Pentax-AWS videolaryngoscope for awake nasal intubation in patients with unstable necks.
In patients with unstable necks and at risk of pulmonary aspiration, awake fibreoptic intubation is often appropriate. However, stabilization of the neck can make fibreoptic intubation more difficult. I report the use of awake nasal intubation using the Pentax-Aiway Scope (AWS) in three patients with restricted neck movement, in whom awake fibreoptic intubation had failed. Case 1: a 59-yr-old m...
متن کاملPentax-AWS videolaryngoscope for awake nasotracheal intubation in patients with a difficult airway.
متن کامل
Comparison of the Pentax AirwayScope and McGrath MAC videolaryngoscope for endotracheal intubation in patients with a normal airway
Various videolaryngoscopes (VLs) have been developed to provide a better laryngeal view and facilitate difficult intubations. The goal of this study was to compare 2 VLs, the Pentax AWS and the McGrath VL, with respect to intubation time and ease of intubation.One hundred forty patients aged 19 to 65 years (American Society of Anesthesiologists classification I or II), who required tracheal int...
متن کاملRapid-Sequence Intubation in the Left-Lateral Tilt Position in a Pregnant Woman with Premature Placental Abruption Utilizing a Videolaryngoscope
Case A 24-year-old pregnant woman was admitted to our hospital with decreased fetal heart rate. Obstetric examination revealed premature placental abruption; emergent caesarean section was planned under general anesthesia. On entering the operating room, the patient showed severe vital sign deterioration (blood pressure, 75/45 mm Hg; heart rate, 142 beats per minute). As left uterine displaceme...
متن کاملA randomized comparison between the Pentax AWS video laryngoscope and the Macintosh laryngoscope in morbidly obese patients.
BACKGROUND The Pentax AWS is a novel video laryngoscope designed to facilitate tracheal intubation by providing indirect visualization of the laryngeal inlet. We sought to compare the intubation success rate and time to intubation for the Pentax AWS and the classic Macintosh laryngoscope. Specifically, we tested the hypothesis that intubation with the Pentax AWS would be easier and faster than ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 64 شماره
صفحات -