We demonstrate a wavelength-locked laser source that rapidly steps through six wavelengths distributed across a 1572.335 nm carbon dioxide (CO(2)) absorption line to allow precise measurements of atmospheric CO(2) absorption. A distributed-feedback laser diode (DFB-LD) was frequency-locked to the CO(2) line center by using a frequency modulation technique, limiting its peak-to-peak frequency drift to 0.3 MHz at 0.8 s averaging time over 72 hours. Four online DFB-LDs were then offset locked to this laser using phase-locked loops, retaining virtually the same absolute frequency stability. These online and two offline DFB-LDs were subsequently amplitude switched and combined. This produced a precise wavelength-stepped laser pulse train, to be amplified for CO(2) measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First Investigation of an All-fiber Versatile Laser Frequency Reference at 2 M for Co2 Lidar Applications

Nowadays, space-borne differential absorption lidar (DIAL) instruments are under investigation by space agencies to monitor the integrated column density or the atmospheric density profile of gaseous species from space to ground. A species of particular interest in the context of greenhouse gases and global climate warming is CO2. Two wavelength ranges at 1572 nm and 2051 nm are being considere...

متن کامل

Analysis of a random modulation single photon counting differential absorption lidar system for space-borne atmospheric CO2 sensing

The ability to observe the Earth’s carbon cycles from space provides scientists an important tool to analyze climate change. Current proposed systems are mainly based on pulsed integrated path differential absorption lidar, in which two high energy pulses at different wavelengths interrogate the atmosphere sequentially for its transmission properties and are back-scattered by the ground. In thi...

متن کامل

Upconversion-based lidar measurements of atmospheric CO2.

For the first time an upconversion based detection scheme is demonstrated for lidar measurements of atmospheric CO2-concentrations, with a hard target at a range of 3 km and atmospheric backscatter from a range of ~450 m. The pulsed signals at 1572 nm are upconverted to 635 nm, and detected by a photomultiplier tube, to test how the upconversion technology performs in a long range detection sys...

متن کامل

Pulsed airborne lidar measurements of atmospheric optical depth using the Oxygen A-band at 765 nm.

We report on an airborne demonstration of atmospheric oxygen optical depth measurements with an IPDA lidar using a fiber-based laser system and a photon counting detector. Accurate knowledge of atmospheric temperature and pressure is required for NASA's Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission, and climate modeling studies. The lidar uses a doubled ...

متن کامل

Profiling atmospheric water vapor using a fiber laser lidar system.

A compact, lightweight, and efficient fiber laser lidar system has been developed to measure water vapor profiles in the lower atmosphere of Earth or Mars. The line narrowed laser consist of a Tm:germanate fiber pumped by two 792 nm diode arrays. The fiber laser transmits approximately 0.5 mJ Q- switched pulses at 5 Hz and can be tuned to water vapor lines near 1.94 microm with linewidth of app...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 50 7  شماره 

صفحات  -

تاریخ انتشار 2011