Quantitative cardiovascular magnetic resonance perfusion imaging: inter-study reproducibility.
نویسندگان
چکیده
AIMS To evaluate the inter-study reproducibility of quantitative cardiovascular magnetic resonance (CMR) myocardial perfusion imaging and the influence of diurnal variation on perfusion. Data on these are limited, despite being crucially important for performing serial examinations both in clinical practice and in trials. METHODS AND RESULTS Sixteen healthy volunteers underwent high-resolution 3 T perfusion imaging three times during a single day to evaluate inter-study reproducibility and the effects of diurnal variation. Absolute perfusion was determined in each coronary artery territory and globally by Fermi constrained deconvolution of myocardial signal intensity curves. Left ventricular (LV) volumes and function were also calculated. Eleven full data sets were suitable for quantitative perfusion analysis. Global rest and stress perfusion and myocardial perfusion reserve (MPR) were 0.6 ± 0.1 and 2.5 ± 0.5 mL/min/g and 4.3 ± 0.9, respectively, for the first scan and were 0.5 ± 0.2 and 2.1 ± 0.5 mL/min/g and 4.2 ± 1.2 for the second (P= 0.1, 0.19, and 0.37, respectively). Inter-study reproducibility was moderate. The coefficient of variation (CV) was 16.0, 26.8, and 23.9% for global rest and stress perfusion and MPR, respectively. The corresponding territorial CVs were 27.5, 35.2, and 33.5%. The reproducibility of LV volumes and function was excellent (CV 4, 7.7, and 4.6% for end-diastolic volume, end-systolic volume, and ejection fraction, respectively). There were no significant detectable diurnal variations in perfusion or LV volumes and function (P≥ 0.05 for all). CONCLUSION The inter-study reproducibility of quantitative myocardial perfusion is reasonable and best for global rest perfusion. No significant diurnal variation in perfusion was observed.
منابع مشابه
Interstudy reproducibility of quantitative perfusion cardiovascular magnetic resonance.
PURPOSE To determine the interstudy reproducibility of quantitative first-pass perfusion cardiovascular magnetic resonance with comparison of 2 previously described analysis techniques. There is no published data on the interstudy reproducibility of perfusion cardiovascular magnetic resonance which can be used to determine the significance of longitudinal changes in myocardial perfusion after p...
متن کاملReproducibility of adenosine stress cardiovascular magnetic resonance in multi-vessel symptomatic coronary artery disease
PURPOSE First-pass perfusion cardiovascular magnetic resonance (CMR) is increasingly being utilized in both clinical practice and research. However, the reproducibility of this technique remains incompletely evaluated, particularly in patients with severe coronary artery disease (CAD). The purpose of this study was to determine the inter-study reproducibility of adenosine stress CMR in patients...
متن کاملReproducibility and inter-observer variability of dobutamine stress CMR in patients with severe coronary disease: implications for clinical research.
PURPOSE The purpose of this study was to analyze reproducibility and inter-observer variability of dobutamine stress cardiac magnetic resonance imaging (dobutamine CMR) and its implications on serial studies. METHODS Nineteen consecutive patients underwent two dobutamine CMR each (median 12 days apart), as part of eligibility criteria for phase I/II stem cell therapy trial. These patients had...
متن کاملCharacteristics and reproducibility of the arterial input function (AIF) derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) studies and its effect on renal functional parameters
Purpose: The aim of this study was to investigate parameters of the aortic input function (AIF) in dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) of the kidney and its effect on renal functional parameters (perfusion and glomerular filtration rate) calculated using a two-compartment model analysis. Inter-observer agreement, effect of size of region of interest (ROI) in the aor...
متن کاملAdenosine stress cardiovascular magnetic resonance with variable-density spiral pulse sequences accurately detects coronary artery disease: initial clinical evaluation.
BACKGROUND Adenosine stress cardiovascular magnetic resonance perfusion imaging can be limited by motion-induced dark-rim artifacts, which may be mistaken for true perfusion abnormalities. A high-resolution variable-density spiral pulse sequence with a novel density compensation strategy has been shown to reduce dark-rim artifacts in first-pass perfusion imaging. We aimed to assess the clinical...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European heart journal cardiovascular Imaging
دوره 13 11 شماره
صفحات -
تاریخ انتشار 2012