Preanalytical errors introduced by sample-transportation systems: a means to assess them.

نویسنده

  • Robin A Felder
چکیده

Sample transportation is one of the major factors contributing to delays in returning high-quality clinical laboratory results to the patient bedside. Furthermore, sample quality can be compromised by exposure to extremes of temperature and physical forces during transportation. Uncontrolled temperature-induced errors are well understood and are often prevented by using environmentally controlled transportation containers. The effects of excessive physical forces applied to medical samples are poorly understood, however. For example, pneumatic tubes are in widespread use for transporting medical samples to the laboratory, because they substantially reduce turnaround times (1 ) and are a less expensive alternative to creating satellite laboratories (2 ). While in transit in pneumatic tubes, samples are subjected to roller coaster–type rapid accelerations during “takeoff,” radial gravitational forces when turning sharp corners, and sudden decelerations when arriving at their destination. These harsh physical forces have long been thought to contribute to preanalytical errors, owing to stress to or even rupture of plasma membranes of erythrocytes and lymphocytes (3– 6 ). Although these previous studies have demonstrated aberrant analytical results due to pneumatic transportation, they have not measured causative factors directly. Recent technological advancements have made it possible to measure the environmental factors that influence medical samples while en route to the laboratory in a pneumatic tube carrier. In a study reported in this issue of Clinical Chemistry, Streichert et al. (7 ) used small recording accelerometers to capture temporal environmental data and correlate it with laboratory-reported values for pediatric blood samples. Subminiature electronic-motion and environmental-factor recorders have been developed because this kind of information is increasingly used in cell phones and gaming devices. The miniaturized electronic 3-axis accelerometer, hygrometer, thermometer, and barometer used in the study of Streichert et al. produced concrete evidence for a causative link between physical forces and changes in serum parameters, demonstrating quite conclusively that the magnitude of the accelerations in the pneumatic tube trip to the laboratory was directly correlated with aberrant serum indices for a large number of analytes. Only potassium, phosphate, lactate dehydrogenase, and aspartate aminotransferase, however, demonstrated changes that were considered critical. The authors went further and replicated their studies in another local hospital. Apparently, the length of the pneumatic tube and the degree of tortuosity of the path to the laboratory are contributory factors that correlate with increased sample errors. Interestingly, temperature, pressure, and humidity showed no significant effects on sample analytes. Although an effect of sample transportation via pneumatic tubes on blood gas concentrations has previously been demonstrated (8 ), this finding was not replicated in the study of Streichert et al., possibly because of the range of unique pneumatic tube path geometries found in each institution. Thus, the authors of this report advocate regular monitoring and controlling of pneumatic tube forces, given that pneumatic tubes are often adjusted or even modified during hospital renovations. Because of these studies, one can anticipate the availability in the near future of a product that enables the monitoring of environmental factors in pneumatic tubes so that they can be adjusted to subthreshold values for the sample stressors. Alternatively, samples at risk for transportation-induced errors, such as those obtained from cancer patients and pediatric patients, could be marked for alternative manual or automated transportation methods. For example, mobile robots have been used quite successfully for the affordable movement of samples throughout a hospital, including riding in elevators (9 ).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Evaluation of Error Types and Turnaround Time of Preanalytical Phase in Biochemistry and Hematology Laboratories

Background& Objective: Each laboratory should determine the type of errors and turnaround time (TAT), especially in the preanalytical phase to report quality and timeliness of the test results. The current study aimed at investigating the common causes of preanalytical errors in biochemistry and hematology laboratories and evaluating the preanalytical ...

متن کامل

Preanalytical Errors in Hematology Laboratory- an Avoidable Incompetence

Background: Quality assurance in the hematology laboratory is a must to ensure laboratory users of reliable test results with high degree of precision and accuracy. Even after so many advances in hematology laboratory practice, pre-analytical errors remain a challenge for practicing pathologists. This study was undertaken with an objective to ...

متن کامل

Quality Assurance in the Preanalytical Phase

The preanalytical phase includes a set of processes that are difficult to define because they take place in different places and at different times. Classically, the preanalytical phase included all processes from the time a laboratory request is made by a physician until the sample is ready for testing. While this definition is very informative, errors that occur at this stage often become app...

متن کامل

Effects of pre-analytical processes on blood samples used in metabolomics studies

Every day, analytical and bio-analytical chemists make sustained efforts to improve the sensitivity, specificity, robustness, and reproducibility of their methods. Especially in targeted and non-targeted profiling approaches, including metabolomics analysis, these objectives are not easy to achieve; however, robust and reproducible measurements and low coefficients of variation (CV) are crucial...

متن کامل

Ten years of preanalytical monitoring and control: Synthetic Balanced Score Card Indicator

INTRODUCTION Preanalytical control and monitoring continue to be an important issue for clinical laboratory professionals. The aim of the study was to evaluate a monitoring system of preanalytical errors regarding not suitable samples for analysis, based on different indicators; to compare such indicators in different phlebotomy centres; and finally to evaluate a single synthetic preanalytical ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 57 10  شماره 

صفحات  -

تاریخ انتشار 2011