Dosimetric and clinical outcomes after volumetric modulated arc therapy for carcinoma of the thoracic esophagus

نویسندگان

  • Cai Xu
  • Mian Xi
  • Ritsuko Komaki
  • Peter A. Balter
  • Meilin Huang
  • Brian P. Hobbs
  • Luhua Wang
  • Steven H. Lin
چکیده

Purpose The efficiency of radiation delivery via volumetric modulated arc therapy (VMAT) is indisputable, but outcomes after VMAT for thoracic esophageal carcinoma are largely unknown. Methods and materials We retrospectively analyzed 65 patients with thoracic esophageal cancer who received VMAT to 50.4 Gy (range, 45-50.4 Gy) with concurrent chemotherapy from November 2012 to March 2016 at a single tertiary cancer center. We then used propensity score matching to match these 65 patients with 130 other patients treated with step-and-shoot intensity modulated radiation therapy (ssIMRT) and concurrent chemotherapy. Differences in continuous and categorical variables were examined with independent-sample t or Wilcoxon tests and χ2 tests. Results Dosimetrically, VMAT had a higher conformity index (87.75 ± 10.70 VMAT vs 83.20 ± 9.42 ssIMRT, P = .003), a higher heart V5, and a lower V50 than ssIMRT, but lung V5-20, heart V30, heart V40, cordmax, and homogeneity index were similar. At median follow-up intervals of 14.3 months (range, 3.8-34.5 months) for VMAT and 31.8 months (range, 1.8-117.2 months) for ssIMRT, overall survival rates were similar between the treatments (93.5% VMAT vs 91.5% ssIMRT at 1 year; 60.0% VMAT and 61.4% ssIMRT at 2 years; P = .868). Recurrence-free survival rates were similar (73.3% VMAT vs 79.5% ssIMRT at 1 year, 59.9% VMAT and 61.8% ssIMRT at 2 years; P = .614), as were pathologic complete response rates (31.2% VMAT vs 23.3% ssIMRT; P = .41) and toxicity and postoperative complications (radiation pneumonitis 9% VMAT vs 15.4% ssIMRT; pericardial effusion 2% VMAT vs 7% ssIMRT; esophageal fistula and stricture 9% VMAT vs 13% ssIMRT; all P > .05). Conclusion Compared with ssIMRT, VMAT had better target conformity with similar organ sparing and comparable rates of survival, recurrence, and toxicity. These results suggest that VMAT can be safe and effective for esophageal cancer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric influence of Flattening Filter (FF) and Flattening Filter Free (FFF) 6 and 10 MV photon beams on Volumetric Modulated Arc Therapy (VMAT) planning in case of prostate carcinoma

Background: In the treatment of prostate cancer, radiotherapy is the potential to increase second primary cancers such as bladder and rectal cancers. The reasons for this potential are more monitor units (MUs), therefore a larger total body dose because of leakage radiation, a bigger volume of normal tissue is exposed to lower radiation doses. This study was designed to compare the integral dos...

متن کامل

Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol

Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...

متن کامل

Dosimetric Effects of Rotational Setup Error in Volumetric Modulated Arc Radiotherapy on Brain Tumor Patients

Introduction: This study examined the dosimetric effects based on the rotational setup error to correct patient setup errors occur during volumetric modulated arc radiotherapy (VMAT) for brain tumor patients. Material and Methods: This study included 1129 cases of cone beam computed tomography (CBCT) images obtained from 46 brain tumor patients, who experienced VMAT and used the 6DoF (degree o...

متن کامل

Quantification and modelling of the dosimetric impact of the treatment couch in volumetric modulated arc therapy (VMAT)

Background: As the volumetric modulated arc therapy (VMAT) becoming a main role of treatment ways, the effect of couch top becomes more significant. It is imperative to re-evaluate the couches that previously may have been considered of no importance during early treatment techniques. The impact of couch top on radiation delivery was explored and the couch model was tested with the aim of reduc...

متن کامل

Predictive factors for acute radiation pneumonitis in postoperative intensity modulated radiation therapy and volumetric modulated arc therapy of esophageal cancer

BACKGROUND Radiation pneumonitis (RP) is a common side reaction in radiotherapy for esophageal cancer. There are few reports about RP in esophageal cancer patients receiving postoperative intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT). This study aims to analyze clinical or dosimetric factors associated with RP, and provides data for radiotherapy planni...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2017