Screen-Film Mammography and Soft-Copy Full-Field Digital Mammography: Comparison in the Patients with Microcalcifications
نویسندگان
چکیده
OBJECTIVE We wanted to compare the ability of screen-film mammography (SFM) and soft-copy full-field digital mammography (s-FFDM) on two different monitors to detect and characterize microcalcifications. MATERIALS AND METHODS The images of 40 patients with microcalcifications(three patients had malignant lesion and 37 patients had benign lesion), who underwent both SFM and FFDM at an interval of less than six months, were independently evaluated by three readers. Three reading sessions were undertaken for SFM and for FFDM on a mammography-dedicated review workstation (RWS, 2K x 2.5K), and for FFDM on a high-resolution PACS monitor (1.7K x 2.3K). The image quality, breast composition and the number and conspicuity of the microcalcifications were evaluated using a three-point rating method, and the mammographic assessment was classified into 4 categories (normal, benign, low concern and moderate to great concern). RESULTS The image quality, the number and conspicuity of the microcalcifications by s-FFDM (on the RWS, PACS and both) were superior to those by SFM in 85.0%, 80.0% and 52.5% of the cases, respectively (p < 0.01), and those by the s-FFDM on the two different monitors were similar in 15.0%, 12.5% and 35.0% of the cases, respectively (p > 0.01). The mammographic assessment category for the microcalcifications in the three reading sessions was similar. CONCLUSION s-FFDM gives a superior image quality to SFM and it is better at evaluating microcalcifications. In addition, s-FFDM with the PACS monitor is comparable to s-FFDM with the RWS for evaluating microcalcifications.
منابع مشابه
A Comparison of the effectiveness of Mammographic Film-Screen and Standard Film-Screen in the Detection of Small Bone Fractures
The use of mammography film-screen is limited in general radiography. The purpose of this study was to compare the effectiveness of mammographic film-screen and standard film-screen systems in the detection of small bone fractures. Radiographs were taken from patients' extremities and neck areas using mammography film-screen and standard film-screen (n=57 each). Fourteen other radiographs were ...
متن کاملComparison of calcification specificity in digital mammography using soft-copy display versus screen-film mammography.
OBJECTIVE The purpose of this study was to compare specificity in the interpretation of calcifications in soft-copy reviewing of digital mammograms versus hard-copy reviewing of screen-film mammograms. MATERIALS AND METHODS A total of 130 consecutive cases with calcifications (44 malignant and 86 benign) that had been evaluated with needle or surgical biopsy were collected. Both screen-film m...
متن کاملThe positive predictive value for diagnosis of breast cancer full-field digital mammography versus film-screen mammography in the diagnostic mammographic population.
RATIONALE AND OBJECTIVES Diagnostic mammography is performed on women with clinical symptoms that suggest breast cancer or women for whom further mammographic evaluation has been requested because of an abnormal screening mammography. We assessed whether the use of full-field digital mammography would improve the positive predictive value (PPV) for the diagnosis of breast cancer in a diagnostic...
متن کاملThe effects of gray scale image processing on digital mammography interpretation performance.
RATIONALE AND OBJECTIVES To determine the effects of three image-processing algorithms on diagnostic accuracy of digital mammography in comparison with conventional screen-film mammography. MATERIALS AND METHODS A total of 201 cases consisting of nonprocessed soft copy versions of the digital mammograms acquired from GE, Fischer, and Trex digital mammography systems (1997-1999) and convention...
متن کاملA comparison of the accuracy of film-screen mammography, full-field digital mammography, and digital breast tomosynthesis.
AIM To measure the change in diagnostic accuracy of conventional film-screen mammography and full-field digital mammography (FFDM) with the addition of digital breast tomosynthesis (DBT) in women recalled for assessment following routine screening. MATERIALS AND METHODS Ethics approval for the study was granted. Women recalled for assessment following routine screening with screen-film mammog...
متن کامل