Influence of abutment design on clinical status of peri-implant tissues.
نویسندگان
چکیده
OBJECTIVE To compare the clinical soft tissue responses around implant tooth-supported 3-unit bridges using tapered abutments with those using butt-joint abutments. METHODS In a split-mouth design study, 8 mm Ankylos (Dentsply Friadent, Germany) implants were placed in the second mandibular molar region of 8 adult Macaca fascicularis monkeys about 1 month after extraction of all mandibular molars. After 3 months of submerged healing, 3-unit metal bridges were constructed. Clinical data was collected by the author who was blind to the abutment selections. Implants were clinically evaluated using Waite plaque index, sulcus bleeding index, probing pocket depth (PPD), probing attachment loss (PAL), and width of keratinized mucosa at baseline (BL) and 3-month and 6-month intervals. Stability of the implant was assessed using Periotest device at BL and after 6 months. RESULTS At BL, all the clinical variables did not differ statistically between the tapered and the butt-joint groups except for PPD (P < 0.05), where the mean PPD was greater in the butt-joint group (2.75 ± 1.02 mm) as compared with the tapered group (1.97 ± 0.65 mm). At the 3-month assessment, there was no difference in all clinical variables. After 6-month loading, no significant difference between these 2 groups was detected in all these variables, with the exception of PAL (P = 0.05) where mean PAL was greater for implants with the butt-joint abutments (0.91 ± 0.86 mm) in comparison with the tapered abutments (0.50 ± 0.88 mm), and mean Periotest values (PTVs) that indicate the tapered-abutment implants (PTV = -4.5 ± 1.60) were more stable than butt-joint-abutment implants (PTV = -1.5 ± 3.59) with P < 0.05. CONCLUSIONS The differences in these mucogingival responses between these 2 groups at BL (during seating of abutments, especially of butt-joint abutments) and after 6-month loading indicated enhanced peri-implant soft tissue stability around the tapered abutments of this system. There was also enhanced-PTV in the test group for clinical mobility assessment after 6-month loading.
منابع مشابه
The impact of the type and configuration of abutments and their (repeated) removal on the attachment level and marginal bone.
PURPOSE The quality and stability of the soft tissue-implant interface is most likely of paramount importance for the preservation of marginal bone and for the long-term prognosis of oral implants. The aim of the present review was to screen existing data in the literature concerning the influence of transmucosal components' composition, type, design and disconnection on peri-implant tissues. ...
متن کاملEvaluation of the Effect of Zirconia and Titanium Abutments on Microleakage of Implant-Abutment Interface Under Oblique Cyclic Loading In Vitro
Background and Aim: Oral bacteria can proliferate in the implant-abutment interface (IAI) and cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to assess the effect of zirconia and titanium abutments on the microleakage of the IAI under oblique cyclic loading conditions. Materials and Methods: In this in-vitro study, 12 implant-abutment assemblies with zirconia...
متن کاملBiologic Width around Dental Implants: An Updated Review
Soft tissue-implant interface is an important anatomical feature contributing to the long-term success of dental implants. Based on the available evidence, different factors may influence biological width around implants including the surgical technique, implant loading, implant surface properties, abutment materials, implant position, and width of the peri-implant mucosa. The purpose of the pr...
متن کاملComparative Evaluation of Microleakage at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study
Abstract Background and aim: Oral microbiota could proliferate the microspace between the implant and abutment, thereby cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microleakage at implant-abutment interface area under oblique cyclic loading in vitro. Materials and methods:In thi...
متن کاملInfluence of Abutment Color and Mucosal Thickness on Soft Tissue Color.
PURPOSE Zirconia (ZrO₂) and titanium nitride (TiN) implant abutments were introduced mainly for esthetic purposes, as titanium's gray color can be visible through mucosal tissues. This study was aimed at assessing whether ZrO₂ and TiN abutments could achieve better esthetics in comparison with titanium (Ti) abutments, regarding the appearance of soft tissues. MATERIALS AND METHODS Ninety pati...
متن کاملMaintenance of Dental Implants: A Review
Objective: Successful bonding of a dental implant to bone, which was referred to as osseointegration by Branemark has been well documented. However, long-term prognosis of an implant depends on adequate maintenance and long-term care. An effective maintenance program is required to preserve the health of peri-implant tissues. Several techniques have been suggested for this purpose but it is n...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Implant dentistry
دوره 18 5 شماره
صفحات -
تاریخ انتشار 2009