A Dose Distribution Study of Uranyl Nitrate in Zebrafish using Liquid Scintillation and Passivated Implanted Planar Silicon Detectors

نویسندگان

  • Lee A. Alleman
  • Huiling L. Nie
  • James Schweitzer
  • Jennifer L. Freeman
  • Shuang Lui
  • Linda Nie
چکیده

Alleman, Lee A. M.S., Purdue University, August 2016. A Dose Distribution Study of Uranyl Nitrate in Zebrafish using Liquid Scintillation and Passivated Implanted Planar Silicon Detectors. Major Professor: Linda H. Nie. Standard curves for a Perkin Elmer TriCarb 2800 liquid scintillation detector (LSC) and a Ludlum 3030p Passivated Implanted Planar Silicon detector have been developed and utilized for studying the dose distribution of depleted uranium (DU) within zebrafish. The DU source was crystallized uranyl nitrate (N2O8U•6H2O) solution, normally used for staining in electron microscopy with a manufactured average specific activity of 0.3 uCi/g. Zebrafish ,both larvae and adults, were exposed to three different mass concentrations, dissected, dissolved and counted using an LSC. The counts were compared to the standard curve correlating the measured activity to that of the mass absorbed. It was found that the larvae were more tolerant to the toxicity of the DU by almost a factor of 10 showing survival up to 200 ppm where the adults had zero survival when exposed to concentrations above 20 ppm. The absorbed DU was observed to concentrate more heavily in the skeletal structure and the blood containing organs (liver and heart) when comparing the relative mass concentrations observed in each organ compared to that of the whole fish exposed to the same concentration. The highest absorbed dose rate was found in the skeletal system at 3.5 mGy/d followed by the blood containing organs at 2.2 mGy/d when exposed to 20 ppm DU. It was also noted that the bioconcentration factors (BCF) of the adult zebrafish followed the same trend observed in similar studies. As the mass concentration of DU was lowered, the BCF calculated for fish exposed increased with a BCF of 130.6 found for those exposed to 20 ppm U and a BCF of 774.2 for fish exposed to 2 ppm. This method shows to present a suitable way of

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of the ZnS(Ag) scintillation detector to the silicon semiconductor detector for quantification of alpha radioactivity in aqueous solutions

A ZnS(Ag) detector was successfully used in the direct detection of alpha particles from aqueous solutions and the results were compared to the passivated ion implanted planar silicon (PIPS) continuous air monitor (CAM) detector. The ZnS(Ag) detector is recommended for on-line detection of gross alpha radioactivity from highlevel liquid waste process streams; however, the detector suffers from ...

متن کامل

مشاهده ی پرتوهای کیهانی با آرایه ی البرز 1

The first phase of the Alborz Observatory Array (Alborz-1) consists of 20 plastic scintillation detectors each one with surface area of 0.25  spread over an area of  realized to the study of Extensive Air Showers around the knee at the Sharif University of Technology campus. The first stage of the project including construction and operation of a prototype system has now been completed and the ...

متن کامل

شبیه‌سازی تابع پاسخ سوسوزن‌های آلی به تابش گاما و نوترون با استفاده از کدهای مونت کارلوی FLUKA،MCNPX و SCINFUL

In organic scintillators, the energy distribution of gamma rays and neutrons is indirectly measured by the pulse height distribution of light output produced through gamma ray and neutron reactions in the detectors. Accurate estimate of the interaction of gamma and neutrons in the detector and produce charged secondary particles and subsequent scintillation light produced in the calculation of ...

متن کامل

New approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras

Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...

متن کامل

بررسی رفتار آشکارساز سوسوزن آرایه رصدخانه البرز با روش شبیه‌سازی مونت کارلو در بستر نرم‌افزاری جیانت۴

For their appropriate temporal resolution, scintillator detectors are used in the Alborz observatory. In this work, the behavior of the scintillation detectors for the passage of electrons with different energies and directions were studied using the simulation code GEANT4. Pulse shapes of scintillation light, and such characteristics as the total number of photons, the rise time and the fallin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2018